NX-6V2 Control
31
XIV. PROGRAMMING
WORKSHEETS
(Factory defaults for segments are in
bold italics
text and "Quick Start" locations are identified with the
L
symbol.)
LOC
PG
DESCRIPTION
DEFAULT
PROGRAM DATA
L
0 11
PHONE
1
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
L
1
11 PHONE 1, ACCOUNT CODE
10 - 10 - 10 - 10 - 10 - 10
_ _ _ _ _ _
L
2
11 PHONE 1, REPORTING FORMAT
0
_
L
3
12 PHONE 1, DIAL ATTEMPTS
BACKUP CONTROL
8
0
_
_
4
12 PHONE 1, SELECTING EVENTS TO REPORT TO PHONE 1
Segment 1 (Circle Numbers To Program)
Segment 2 (Circle Numbers To Program)
1
=
Alarms and Restores
2 =
Open/Close
3 =
Bypass
4 =
Zone Trouble
5 =
Power Trouble (AC Failure or Low Battery)
6 =
Siren & Telephone Fault
7 =
Test Reports
8 =
Program, Download, & Log Full
1 =
Tampers
2 =
Short Circuit & Ground Fault
3 =
Sensor Lost
4 =
Sensor Low Battery
5 =
Expander Trouble
6 =
Failure To Communicate
7 =
Zone Activity Monitor
8 =
Reserved
5
12 PHONE 1, SELECTING WHICH PARTITIONS REPORT TO PHONE 1
Segment
1
(Circle Numbers To Program)
1 = Partition 1
2 = Partition 2
L
6 12
PHONE
2
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
L
7
12 PHONE 2, ACCOUNT CODE
10 - 10 - 10 - 10 - 10 - 10
_ _ _ _ _ _
L
8
13 PHONE 2, REPORTING FORMAT
0
_
9
13 PHONE 2, DIAL ATTEMPTS
BACKUP CONTROL
8
0
_
_
10
13 PHONE 2, SELECTING EVENTS TO REPORT TO PHONE 2
Segment 1 (Circle Numbers To Program)
Segment 2 (Circle Numbers To Program)
1 = Alarms and Restores
2 = Open/Close
3 = Bypass
4 = Zone Trouble
5 = Power Trouble (AC Failure or Low Battery)
6 = Siren & Telephone Fault
7 = Test Reports
8 = Program, Download, & Log Full
1 = Tampers
2 = Short Circuit & Ground Fault
3 = Sensor Lost
4 = Sensor Low Battery
5 = Expander Trouble
6 = Failure To Communicate
7 = Zone Activity Monitor
8 = Reserved
11
13 PHONE 2, SELECTING WHICH PARTITIONS REPORT TO PHONE 2
Segment
1
(Circle Numbers To Program)
1 = Partition 1
2 = Partition 2
12
13
PHONE
3
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
13
14 PHONE 3, ACCOUNT CODE
10 - 10 - 10 - 10 - 10 - 10
_ _ _ _ _ _
14
14 PHONE 3, REPORTING FORMAT
0
_
15
14 PHONE 3, DIAL ATTEMPTS
BACKUP CONTROL
8
0
_
_
16
14 PHONE 3, SELECTING EVENTS TO REPORT TO PHONE 3
Segment 1 (Circle Numbers To Program)
Segment 2 (Circle Numbers To Program)
1 = Alarms and Restores
2 = Open/Close
3 = Bypass
4 = Zone Trouble
5 = Power Trouble (AC Failure or Low Battery)
6 = Siren & Telephone Fault
7 = Test Reports
8 = Program, Download, & Log Full
1 = Tampers
2 = Short Circuit & Ground Fault
3 = Sensor Lost
4 = Sensor Low Battery
5 = Expander Trouble
6 = Failure To Communicate
7 = Zone Activity Monitor
8 = Reserved
Содержание NetworX NX-6V2
Страница 5: ...NX 6V2 Control 5 IV WIRING DIAGRAM ...
Страница 30: ...30 NX 6V2 Control NOTES ...
Страница 51: ......