Segment 4:

 

1 =  On if Fail To Communicate report enabled. 
2 =  On if Log Full report enabled. 
3 =  On if Autotest report enabled. 
4 =  On if Start/End programming report enabled. 
5 =  On if End Download report enabled. 
6 =  On if Sensor Low Battery report enabled. 
7 =  On if Sensor Missing report enabled. 
8 =  On if First to Open / Last to Close. 

 

Segment 5: 

 

1 =  On enable Lost Clock service light. 
2 =  On enables Zone Doubling (requires NX-200 Zone Doubling Kit). 
3 =  On disables On-Board 6 zones. 
4 =  On will allow two trips on same cross-zone to activate an alarm. 
5 =  On will 

not

 allow zones that are force armed to report bypass. 

6 =  Reserved. 
7 =  Use internal crystal for clock.  
8 =  Disable Temporal Siren on Fire. NOTE: Do NOT disable for UL listed systems. 

 
Segment 6:

 

 

1 =  Enable 2 wire smoke. 
2 =  Reserved. 
3 =  Enable for Zone Activity in Hours (not Days) 
4 =  Enable Daylight Savings Time (DST)  
5 =  Reserved 
6 =  On to disable Clean Me report (At default, bit is OFF = enabled) 
7 =  On to disable Start/End Test report (At default, bit is OFF = enabled) 
8 =  Reserved. 

 

Segment 7:

 Reserved 

 

38 SWINGER 

SHUTDOWN 

COUNT 1............. numerical 

Location 38 contains the number of trips during an arming cycle that the NX-6V2 will allow before bypassing a zone. The count 
determination is described in the Glossary. 

Factory default is 1.

 

 

L

 

39 

KEYPAD SOUNDER CONTROL 1............. feature 

select 

Segment 1:

 

 

1 =  On if keypad sounds for 

A

Telephone Line Cut

@

 when the system is armed. 

2 =  On if keypad sounds for 

A

Telephone Line Cut

@

 when disarmed. 

3 =  On if keypad sounds upon AC Power Failure. 
4 =  On if keypad sounds when a Low Battery is detected. 
5 =  On if keypad sounds during Cross Zone trip time. 
6 =  On if keypad sounds for zone and box tampers. 
7 =  Reserved. 
8 =  On if keypad sounds for expander trouble (required for UL installations). 

 

40 SYSTEM 

TIMERS 

14........... numerical 

Location 40 contains the duration of various system timing functions.  Example: If you desire the duration of the Dynamic Battery Test 
to be 30 minutes, you should program [3]-[0]-[

r

] in segment 1 of this location.  The [3]-[0] is the number of minutes, and the [

r

] stores 

the data and moves to the next segment of this location. 
 

NOTES FOR UL INSTALLATIONS 

The "Listen-In" feature cannot be enabled for UL Listed systems. 
The "Dynamic Battery Test" feature cannot exceed four (4) hours. 
The dial delay shall be set to -0-. 

 

Segment 1 

-  

Dynamic Battery Test duration in minutes 0-255 minutes ..................................... (0 = no test) 

Segment 2

  - 

AC Fail report delay in minutes 0-255 minutes. .................................................... (0 = no delay) 

Segment 3

 - 

Power Up Delay in seconds 0-60 seconds ........................................................... (0 = no power up delay) 

Segment 4

 -  

Siren Time in minutes 1-254 minutes. 

Segment 5

 -  

Telephone Line Cut delay in seconds 0-255 seconds........................................... (0 = no TLM) 

Segment 6

 -  

Cross Zone time in minutes 0-255 ........................................................................ (0 = no cross zoning)  

Segment 7

 -  

Chime time in 50 mS (1/20th second) increments from 0-12 seconds.................. (0 = follows zone 255 latched) 

Segment 8

 - 

Dial delay in seconds 15-255 seconds 

Содержание NetworX NX-6V2

Страница 1: ...NetworX Series NX 6V2 Control Panel Installation and Startup Downloaded from http www guardianalarms net ...

Страница 2: ...tents be disclosed to any third party without the written approval of GE Security Please refer to the current GE Security product catalog for detailed warranty information Main 800 727 2339 Technical Support 800 727 2339 Outside the US 903 845 6941 Tech Support Fax 903 845 8409 Main Fax 903 845 6811 Sales Literature 800 547 2556 Web www caddx com www ge security com SAFETY SYMBOLS Warning Indicate...

Страница 3: ...RAMMING DATA TYPES 9 NUMERICAL DATA 9 FEATURE SELECTION DATA 9 PROGRAMMING EXAMPLE 10 IX LOADING FACTORY DEFAULTS 11 X ENROLLING MODULES AND KEYPADS 11 XI L QUICK START INSTALLATION 11 XII PROGRAMMING LOCATIONS 11 REPORTING EVENTS TO PHONE NUMBER 1 12 REPORTING EVENTS TO PHONE NUMBER 2 13 REPORTING EVENTS TO PHONE NUMBER 3 14 XIII DEFAULT ZONE TYPES CONFIGURATIONS 16 XIV PROGRAMMING WORKSHEETS 31 ...

Страница 4: ...odule NX 1248E 48 Zone LCD Keypad NX 320E Smart Power Supply and Buss Extender NX 1308E 8 Zone LED Door Design Keypad NX 408E 8 Zone Wireless Expansion Module UL listed part 60 904 NX 1316E 16 Zone LED Door Design Keypad NX 416E 16 Zone Wireless Expansion Module UL listed part 60 904 NX 1324E 24 Zone LED Door Design Keypad NX 448E 48 Zone Wireless Expansion Module UL listed part 60 904 NX 1448E 48...

Страница 5: ...NX 6V2 Control 5 IV WIRING DIAGRAM ...

Страница 6: ...s Individually this terminal is limited to 1 Amp Combined this terminal and KP POS are limited to 2 amps total current ZONE 6 Connect to one side of zone 6 loop Connect the other side to com terminal Open or short causes alarm Only Zone 6 can used for a two wire smoke detector connected with a 680 Ω E O L resistor Refer to the wiring diagram Program location 37 segment 6 option 1 Only zone 6 can b...

Страница 7: ... was accepted 7 SUPPRESSES THE SERVICE LED NOTE For UL installations the Service LED shall not be suppressed Will not allow the Service LED to illuminate for any reason If there is a system trouble pressing r 2 will still show the service menu 8 ENABLE MULTI PARTITION VIEWING Enables temporary viewing of all partitions by pressing r 1 partition number r 9 4 Set Keypad Number and Partition Enter r ...

Страница 8: ...essing r 9 8 while the system is disarmed will cause the control to do a callback for a download NOTE A valid user code may be required after r 9 8 if enabled in location 41 page 20 r 9 9 Pressing r 9 9 while the system is disarmed will cause the control panel to seize the phone line for a download NOTE A valid user code may be required after r 9 9 if enabled in location 41 page 20 VII PROGRAMMING...

Страница 9: ...of these LEDs are as follows Zone 1 LED 1 Zone 2 LED 2 Zone 3 LED 4 Zone 4 LED 8 Zone 5 LED 16 Zone 6 LED 32 Zone 7 LED 64 Zone 8 LED 128 Example If the numerical data to be programmed in a location is 66 press 6 6 on the keypad The LEDs for Zone 2 and Zone 7 will become illuminated indicating 66 is in that location 2 64 66 See this example on page 10 Once the data is programmed press r to enter t...

Страница 10: ...nging the data in the current segment FIGURE 2 Feature Selection Data Location 23 Segment 1 1 Quick Arm 2 Re Exit 3 Auto Bypass 4 Silent Keypad Panic 5 Audible Keypad Panic 6 Keypad Auxiliary 1 7 Keypad Auxiliary 2 8 Multi Keypad Tamper Press the key on the numeric keypad that corresponds to the feature you wish to enable disable When an LED is on a feature is enabled when off the feature is disab...

Страница 11: ... will prevent successful connection to the central station L 1 ACCOUNT CODE FOR PHONE 1 6 numerical The account code sent when Phone 1 is dialed is programmed in location 1 Program a A10 in the segment immediately after the last digit of the account code If the account code is 6 digits long program all 6 segments L 2 COMMUNICATOR FORMAT FOR PHONE 1 1 numerical Location 2 contains the communicator ...

Страница 12: ...ould be used to select those partitions that should be reported to Phone 1 If no events should be reported to Phone 1 both locations should be programmed as 0 disabling all options 4 EVENTS REPORTED TO PHONE 1 2 feature select Segment 1 1 Alarms and Alarm Restores 2 Opening and Closings 3 Zone Bypass and Bypass Restores 4 Zone Trouble and Trouble Restores 5 Power Fail Low Battery Power Restore and...

Страница 13: ...cation 11 is used to select which partitions are reported to Phone 2 If dual or split reporting is not desired location 10 and location 11 should be left at the factory default of 0 If multi reporting or split reporting is desired and the split is based on the event type such as alarm open close etc location 10 should be used to select only those events that should be reported to Phone 2 and locat...

Страница 14: ...will be made to Phone 3 the next two attempts to Phone 2 then repeating until the total number of attempts designated in Segment 1 is completed REPORTING EVENTS TO PHONE NUMBER 3 Phone 3 can be used for a third receiver to multi report or split report events Phone 3 has two programming locations that are used to select which events are reported to this phone number Location 16 is used to select wh...

Страница 15: ...from the keypad when Off 8 On enables call back at auto test interval L 22 DOWNLOAD CALL BACK NUMBER 20 numerical If a telephone number is programmed into this location and Require Callback is enabled in location 21 the control panel will hang up for approximately 36 seconds ensuring that the calling party has disconnected and then call back If tone dialing is desired program an 15 in the segment ...

Страница 16: ...ones designated as delay 2 Valid entries are 45 255 seconds Segments 5 6 Reserved XIII DEFAULT ZONE TYPES Configurations Zones can be programmed to be one of thirty different zone types configurations Zone types 17 20 can be used for wireless or hardwired zones using European double EOL configuration The default zone types are listed below These zone types can be customized by programming location...

Страница 17: ... used to enable tamper on a wireless transmitter 19 INSTANT WITH TAMPER ENABLED This zone creates an instant alarm whenever it is tripped and the Armed LED is on This zone type can be used to enable tamper on a wireless transmitter 20 ENTRY EXIT DELAY 2 WITH TAMPER ENABLED A trip will start entry delay 2 The lack of a trip during exit delay will enable the Automatic Bypass or Instant mode if so pr...

Страница 18: ...ne 16 Segments 1 8 1 Partition 1 2 Partition 2 29 36 RESERVED L 37 SIREN AND SYSTEM SUPERVISION 7 feature select Location 37 is used to enable various system feature and reporting options For specific definitions refer to the Glossary beginning on page 39 Segment 1 1 On if siren sounds for Telephone Line Cut when armed 2 On if siren sounds for Telephone Line Cut when disarmed 3 On if siren blast a...

Страница 19: ...select Segment 1 1 On if keypad sounds for ATelephone Line Cut when the system is armed 2 On if keypad sounds for ATelephone Line Cut when disarmed 3 On if keypad sounds upon AC Power Failure 4 On if keypad sounds when a Low Battery is detected 5 On if keypad sounds during Cross Zone trip time 6 On if keypad sounds for zone and box tampers 7 Reserved 8 On if keypad sounds for expander trouble requ...

Страница 20: ... the Go To Program Code can be used to enter the Program Mode 43 GO TO PROGRAM CODE PARTITION AUTHORIZATION 2 feature select The Go To Program Code can be used as a standard arm disarm code When using the code to arm or disarm the user ID is 255 This code may not be changed in the Run Mode Segment 1 1 Reserved 2 On enables Go To Program Code as an arm only code 3 On enables Go To Program Code as a...

Страница 21: ...50 AUXILIARY OUTPUT 4 EVENT TIME 2 numerical Segment 1 Use Table XIII 1 to select the event that will activate Auxiliary Output 4 Segment 2 Program the timing from 0 255 minutes or seconds depending on data programmed in Segment 4 Location 46 Programming a 0 makes the output follow the event Table XIII 1 AUXILIARY OUTPUT EVENT SELECTION DATA EVENT DATA EVENT DATA EVENT 0 Burglary Alarm 19 Exit 38 ...

Страница 22: ...ram the hour of the closing auto arm time Segment 2 Program the minutes after the hour of the closing auto arm time 54 DAYS OF WEEK EACH PARTITION IS OPEN 2 feature select Location 54 selects which days of the week each partition is open On these days Aarm only after close window codes will be able to arm and disarm during open window NOTE If any partition is not programmed to be opened and is pro...

Страница 23: ...zone Sensor Missing for a 4 2 format Box on pg 23 Segment 1 Partition 1 Segment 2 Partition 2 62 DURESS COMMUNICATOR CODE 2 numerical Location 62 contains the digits that will be sent for a 4 2 format if the Duress code is enabled in location 44 Box on pg 23 63 KEYPAD AUXILIARY 1 COMMUNICATOR CODE 2 numerical Location 63 contains the digits that will be sent for a 4 2 format if the keypad Auxiliar...

Страница 24: ... 2 numerical Location 76 contains the digits for a 4 2 format if the Log Full Reporting is enabled Box on pg 23 77 OPENING COMMUNICATOR CODE 2 numerical Location 77 contains the digit of a 4 2 format if the Opening Reporting is enabled Box on pg 23 Segment 1 Partition 1 Segment 2 Partition 2 78 CLOSING COMMUNICATOR CODE 2 numerical Location 78 contains the digit of a 4 2 format if the Closing Repo...

Страница 25: ...artition 1 will be used Segment 1 Entry time 1 Entry time that will be used when a Delay 1 zone type initiates an entry delay Segment 2 Exit time 1 Exit time that will be used for all zones designated as Delay 1 Segment 3 Entry time 2 Entry time that will be used when a Delay 2 zone type initiates an entry delay Segment 4 Exit time 2 Exit time that will be used for all zones designated as Delay 2 ...

Страница 26: ...ort The desired event code should be chosen from the list on page 43 The zone ID will be that zone that is in alarm If 4 2 format is being used refer to Location 110 on page 25 for details 117 ZONE TYPE 4 CHARACTERISTIC SELECT 5 feature select Use Zone Type Characteristic Selections described in Location 111 page 25 118 ZONE TYPE 5 ALARM EVENT CODE 1 numerical Location 118 contains the event code ...

Страница 27: ...ACTERISTIC SELECT 5 feature select Use Zone Type Characteristic Selections described in Location 111 page 25 136 ZONE TYPE 14 ALARM EVENT CODE 1 numerical Location 136 contains the event code sent for a Contact ID or SIA report The desired event code should be chosen from the list on page 43 The zone ID will be that zone that is in alarm If 4 2 format is being used refer to Location 110 on page 25...

Страница 28: ...RACTERISTIC SELECT 5 feature select Use Zone Type Characteristic Selections described in Location 111 page 25 156 ZONE TYPE 24 ALARM EVENT CODE 1 numerical Location 156 contains the event code sent for a Contact ID or SIA report The desired event code should be chosen from the list on page 43 The zone ID will be that zone that is in alarm If 4 2 format is being used refer to Location 110 on page 2...

Страница 29: ...code should be chosen from the list on page 43 The zone ID will be that zone that is in alarm If 4 2 format is being used refer to Location 110 on page 25 for details 169 ZONE TYPE 30 CHARACTERISTIC SELECT 5 feature select Use Zone Type Characteristic Selections described in Location 111 page 25 170 205 RESERVED 206 AUTO DISARM DAY SELECTION 8 feature select Location 206 selects which days each pa...

Страница 30: ...30 NX 6V2 Control NOTES ...

Страница 31: ...DE 10 10 10 10 10 10 _ _ _ _ _ _ L 8 13 PHONE 2 REPORTING FORMAT 0 _ 9 13 PHONE 2 DIAL ATTEMPTS BACKUP CONTROL 8 0 _ _ 10 13 PHONE 2 SELECTING EVENTS TO REPORT TO PHONE 2 Segment 1 Circle Numbers To Program Segment 2 Circle Numbers To Program 1 Alarms and Restores 2 Open Close 3 Bypass 4 Zone Trouble 5 Power Trouble AC Failure or Low Battery 6 Siren Telephone Fault 7 Test Reports 8 Program Downloa...

Страница 32: ... __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ L 23 15 PARTITION 1 FEATURE SELECTION Segment 1 Circle Numbers To Program 1 Quick Arm 2 Re Exit 3 Auto Bypass 4 Silent Panic 5 Audible Panic 6 Auxiliary 1 7 Auxiliary 2 8 Multi Keypress Tamper Segment 2 Circle Numbers To Program 1 LED extinguish enable 2 Require user code for bypassing zones 3 Bypass sounder alert 4 AC power low battery sounde...

Страница 33: ... report enabled 2 AC Fail report enabled 3 Low Battery report enabled 4 Auxiliary power over current report enabled 5 Siren supervision report enabled 6 Telephone Line Cut report enabled 7 Ground Fault Detection report enabled 8 Expander trouble report enabled Segment 4 Circle Numbers To Program 1 Failure To Communicate report enabled 2 Log Full report enabled 3 Autotest report enabled 4 Start and...

Страница 34: ...ng with keyfob or keyswitch 6 8 Reserved Do not program L 42 20 GO TO PROGRAM CODE 9 7 1 3 0 0 _ _ _ _ _ _ 43 20 GO TO PROGRAM CODE PARTITION AND AUTHORIZATION Segment 1 Circle numbers to program 1 Reserved 2 Enables Go To Program Code as an arm only code 3 Enables Go To Program Code as an arm only after closing 4 Enables Go To Program Code as a master arm disarm code can change user codes 5 Enabl...

Страница 35: ...m event code The zone ID or user ID will always be reported as the lower HEX digit 1 F For example if the zone ID or user ID is 15 the 4 2 lower digit will be F Refer to Appendix 4 on page Error Bookmark not defined If Segment 2 is left as 0 unprogrammed it will follow the Segment 1 selection If Segment 1 is left as 0 and the feature is enabled the NX 6V2 will report A LOC PG DESCRIPTION DEFAULT P...

Страница 36: ...nt 8 Reserved Segment 3 1 Open Close 2 Bypass 3 Restore 4 Trouble 5 Tamper 6 Cancel 7 Recent Closing 8 Exit Error Segment 4 1 Late to Close Early to Open 2 8 Reserved Segment 5 Reserved 91 25 PARTITION 2 ENTRY EXIT TIMERS Segment 1 Entry Time 1 0 _ Segment 2 Exit Time 1 0 _ Segment 3 Entry Time 2 0 _ Segment 4 Exit Time 2 0 _ Segment 5 6 Reserved 92 109 25 RESERVED 110 25 ZONE TYPE 1 ALARM EVENT C...

Страница 37: ... __ __ __ 134 ZONE TYPE 13 ALARM EVENT CODE 4 __ 135 ZONE TYPE 13 CHARACTERISTIC SELECT 0 12458 5678 0 0 __ __ __ __ __ 136 ZONE TYPE 14 ALARM EVENT CODE 7 __ 137 ZONE TYPE 14 CHARACTERISTIC SELECT 5 12456 5678 0 0 __ __ __ __ __ 138 ZONE TYPE 15 ALARM EVENT CODE 5 __ 139 ZONE TYPE 15 CHARACTERISTIC SELECT 457 1256 5678 0 0 __ __ __ __ __ 140 ZONE TYPE 16 ALARM EVENT CODE 4 __ 141 ZONE TYPE 16 CHA...

Страница 38: ...205 RESERVED 206 DAYS OF THE WEEK AUTO DISARMING WILL OCCUR IN PARTITIONS Segments Sunday Monday Tuesday Wednesday Thursday Friday Saturday Reserved Partition 1 Partition 2 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 ZONE WORKSHEET 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8 16 NOTES ...

Страница 39: ...hese features ADialer Delay must be enabled in the ACharacteristic Select of locations 110 169 Zone Types Loc 41 pg 20 Auto Test This feature will cause the panel to call the central station to report a communicator test at a specified interval Loc 51 pg 22 Auxiliary Outputs The NX 6V2 has 4 programmable outputs that can be used to activate relays LED s etc See the terminal description on pg 6 and...

Страница 40: ... expansion device number that will report can be found on page 45 Loc 37 pg 18 Fail to Communicate The NX 6V2 will illuminate the Service LED if a report fails to reach the central station If enabled when the next report is successfully communicated a Fail to Communicate code will be reported Loc 37 pg 18 Fire Alarm Verification When enabled the NX 6V2 will verify a Fire alarm by requiring more th...

Страница 41: ...rt the exit delay for a quick exit without disarming the system by pressing the Exit key while the system is armed Loc 23 pg 15 Shutdown When enabled the keypads will turn off all LED s except the Power LED and not accept keypresses Loc 21 pg 15 Siren Blast For Arming The NX 6V2 can be programmed to give a one second siren blast when the panel is armed at the end of the exit delay or when the cent...

Страница 42: ...wise the AWalk Test Mode will automatically exit after 15 minutes Loc 41 pg 20 Wireless Sensor Missing Low Battery The NX 6V2 will send a report to the central station when a wireless sensor has detected a low battery or has not reported to the receiver The Service LED will illuminate when either condition exists Loc 37 pg 18 Zone Activity Monitor This feature will send a report to the central sta...

Страница 43: ...K KEYPAD AUXILIARY 1 110 FA KEYPAD AUXILIARY 2 100 MA KEYPAD PANIC audible 120 PA KEYPAD PANIC silent 121 HA KEYPAD TAMPER 137 TA LOW BATTERY device number 309 YT LOW BATTERY RESTORE device number 309 YR MANUAL TEST 601 RX OPEN user number 401 OP RECENT CLOSE user number 401 CR RF SENSOR LOST zone number 381 T RF SENSOR RESTORE zone number 381 R SENSOR BATTERY RESTORE zone number 384 XR SENSOR LOW...

Страница 44: ... Alarm 17 WA Water Alarm 18 QA Emergency Alarm 19 SA Sprinkler Alarm 20 ZA Freeze Alarm 21 KH High Temp Alarm 22 FA Manual Fire Alarm The NX 6V2 has the ability to report Ademco Contact ID transmissions Each report in Contact ID consists of an Event Code and a Zone ID The zone ID is the zone that created the alarm The event code will come from the chart below and be programmed in the zone type eve...

Страница 45: ... 2 3 on 90 Switches 2 3 on 33 Switches 1 2 3 on 91 Switch 1 2 3 on 34 OUTPUT MODULE NX 508E Switch Setting Address Switch Setting Address Switch Setting Address Switch 1 2 on 24 Switch 2 3 on 27 Switch 1 on 30 Switch 3 on 25 Switch 1 2 3 on 28 Switch 2 on 31 Switch 1 3 on 26 All switches off 29 XIX APPENDIX 4 USER ID OR ZONE ID HEX DIGIT FOR 4 2 FORMATS The following appendix applies only to slow ...

Страница 46: ... the equipment from the telephone line to determine if it is the customers equipment that is not functioning properly If the problem is with the device the customer shall discontinue use until it is repaired EQUIPMENT INFORMATION Manufacturer Of Connecting Equipment CADDX CONTROLS INC FCC Registration Number US GCQAL01BNX V2 RINGER EQUIVALENCE 0 1 B XXI INDUSTRY CANADA INFORMATION NOTICE The Indus...

Страница 47: ...e networks in the countries marked with a check and may have interworking problems with the countries that are not checked Due to the inherent differences in the individual PSTNs certain software settings may need to be adjusted on a country to country basis If it is desired to use this equipment on a network other than the one on which it was originally installed you should contact your equipment...

Страница 48: ...s the fire initiating circuits shall not be connected The Entry Guard feature shall be disabled Group Bypassing shall be disabled Delay before dial seizure shall be set to 0 Total current draw from aux power connections at terminal positions POS AUX PWR and SMOKE PWR must not exceed 400 mA Remote Downloading shall not be used on UL listed systems For residential burglary applications the maximum e...

Страница 49: ...H 1 Amp 400 mA 34 AH 1 Amp 200 mA 17 AH 1 Amp Calculations based on three 17 Amp batteries K IMPORTANT If separate power supplies are necessary to accommodate additional devices safety standards require that each power supply be prominently marked with adequate instructions for removing all power from the unit Dispose of used batteries according to the manufacturer s instructions and or local gove...

Страница 50: ...g Entry Delay s Entry 1 Delay 24 1 30 30 240 sec Entry 2 Delay 24 3 30 30 240 sec Abort Window for Non Fire Zones Dialer Delay 40 8 30 Enabled may be disabled by zone zone type Abort Window Time for Non Fire Zones Dialer Delay 40 8 30 15 45 sec NOTE Combined Abort window and Entry Delay must not exceed 1 minute Abort Annunciation This feature is non programmable in the panel Flashing Cancel LED go...

Страница 51: ......

Страница 52: ...2 to 120 degrees F LED KEYPAD Current Draw 130 mA max Zones Normal w o Sounder 55 mA Dimensions 6 4 Wide 4 0 High 1 1 Deep NX148E LCD KEYPAD Current Draw 110 mA max w o Sounder 75 mA Dimensions 6 4 Wide 5 3 High 1 0 Deep METAL ENCLOSURE DIMENSION 11 25 Wide 11 25 High 3 50 Deep SHIPPING WEIGHT 9 lbs 1420 NORTH MAIN STREET GLADEWATER TEXAS 75647 Main 800 727 2339 Technical Support 800 727 2339 Outs...

Отзывы: