63
5.2.50 Timer Control - 5600 Model
CAUTION. Switch off electrical power supply.
5.2.50.1 First remove the timer control knob from the shaft.
Prior to removing the timer control, release the adhesive
tape which holds the drip sheet over the timer control.
Remove the two mounting screws and remove the drip
sheet.
NOTE: The long wrap of the drip sheet is to the top of the
control panel.
5.2.50.2 On the left hand side face of the timer control is
located the electrical input/output 1/4" terminals mounted on
a printed circuit board. The wiring harness connections to
the timer control are grouped into three white nylon block
connectors. These are plugged into the three rows of
terminals mounted on the side face of the timer control.
NOTE: On the top right corner of each white nylon block
connector is a small rectangular locator, 3/16" long by 3/32"
wide. The locator is used to identify the top of the block
connector. Ensure each locator is to the top face of the timer
control.
Remove 2 screws
Nylon blocks marked accordingly
5.2.49 Door Lock Microswitch Lever - 5600, 5700
& 5900 Models
CAUTION. Switch off electrical power supply.
5.2.49.1 To remove the door lock microswitch lever, first
remove the door lock microswitch (Section 5.2.48).
5.2.49.2 Exert pressure against the flanged head of the
pivot point of the microswitch lever. The pivot point will spring
from the control panel carrier frame.
5.2.49.3 Twist the microswitch lever and remove from the
front central square aperture of the control panel carrier
frame.
5.2.49.4 Reassemble the dishwasher in reverse order.
5.2.49.5 Operate and test the dishwasher before leaving.
Содержание Monogram ZBD5600
Страница 1: ...g GE Consumer Service Training TECHNICAL SERVICE GUIDE ZBD5900 ZBD5700 ZBD5600 Dishwashers ...
Страница 70: ...69 6 5 Wiring Diagram 5700 5900 Models Important Check all wiring connections before reconnecting to supply ...
Страница 71: ...70 6 4 Sequence Chart 5600 Model ...
Страница 72: ...71 6 5 Wiring Diagram 5600 Model Important Check all wiring connections before reconnecting to supply ...