![GE Monogram ZBD5600 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/ge/monogram-zbd5600/monogram-zbd5600_technical-service-manual_2199561029.webp)
28
Drain Pump Circuit (step 7): The drain pump circuit is a direct circuit from the ON/OFF function within the timer control, to the
“DRAIN” contact, also within the timer control. The drain pump circuit is dependant upon the completion of the
“Rinse”
program.
• The pressure switch must reset to empty (continuity between No. 1 - No. 2) for the timer motor to advance the drain cam for
40 seconds pump out time and completion of the
“Rinse”.
• The drain pump itself must also be efficient/operative to enable a quantity of water to be pumped from the tub, in order for
the pressure switch to sense the reduction in water level and reset to the No. 1 to No. 2 continuity conditions.
• Following the 40 second drain pump operation, the timer motor advances the timer control to the “end of cycle” position,
wherein the
“Rinse” program is completed.
4.5.3 Super Wash Program
The Super Wash program consists of a total of 32 steps of the timer control. The initial step starts at step 10 as a drain mode
which is identical to step 3 for the
“Rinse” program. Steps 11 and 12 “Fill & Circulate” are identical to steps 4 and 5 for the
“Rinse” program.
4.5.3.1 CIRCULATE and HEAT T+20 (step 13):
Step 13 is a heating function, where the heater circuit is completed through the pressure switch in a satisfied mode,
(continuity between No. 1 and No. 3 terminals).
Circuit Diagram: Circulate and Heat t+20 (Step 13)
Содержание Monogram ZBD5600
Страница 1: ...g GE Consumer Service Training TECHNICAL SERVICE GUIDE ZBD5900 ZBD5700 ZBD5600 Dishwashers ...
Страница 70: ...69 6 5 Wiring Diagram 5700 5900 Models Important Check all wiring connections before reconnecting to supply ...
Страница 71: ...70 6 4 Sequence Chart 5600 Model ...
Страница 72: ...71 6 5 Wiring Diagram 5600 Model Important Check all wiring connections before reconnecting to supply ...