32
4.5.5 Fill Time Switch
A fill time of 80 seconds is factory set using the fill time switch. For low pressure gravity fed hot water systems or any other low
water pressure installation, the fill time switch should be engaged to increase the fill time. To check the fill time, run the
dishwasher on the “Rinse + Hold” program three times and check the water level. If the water level is not between the “MAX”
& “MIN” marks on the lower spray arm support as shown in section 4.3, then the fill time switch will need to be engaged.
Refer to section 5.1 to access the fill time switch.