6
Figure 2 764 Controller Identification
Figure 3 Remote Start/Multi-Tank Lockout Cable
Figure 4 Twin Sensor Cable
Figure 5 Twin Cable Extension
Location Selection
Location of a water conditioning system is important. The
following conditions are required:
•
Level platform or floor.
•
Room to access equipment for maintenance and
adding regenerant (salt) to tank.
•
Ambient temperatures over 34
o
F (1
o
C) and below
120
o
F (49
o
C).
•
Water pressure below 100 psi (6.89 bar) and above 25
psi (1.7 bar).
•
In Canada the water pressure must be below 100 psi
(6.89 bar).
•
Constant electrical supply to operate the controller.
•
Total minimum pipe run to water heater of ten feet
(three meters) to prevent backup of hot water into
system.
•
Local drain for discharge as close as possible.
•
Water line connections with shutoff or bypass valves.
•
Must meet any local and state codes for site of
installation.
•
Valve is designed for minor plumbing misalignments.
Do not support weight of system on the plumbing.
•
Be sure all soldered pipes are fully cooled before
attaching plastic valve to the plumbing.
Time & Day
Regen Time & Day
Salt
SU MO TU
WE TH FR SA
g/L
PM
MIN
KG
x100
x2
P
H
C
Capacity
Hardness
Lbs/ft³
LCD Display
Manual Regen Button
Down Button
Set Button
Up Button
Turbine Input
Main Motor &
Optical Sensor
Connection
AC Adapter
(low voltage)
Input
Front
Back
Extension Cable
Connection
No-Salt Detector
(Chlorine Generator)
Connection (not used
Lockout & Remote
Connection
Regen/Start
Multi Single Tank
Dry Contact Signal Input
on Magnum Valves)
Содержание Logix 764
Страница 2: ......
Страница 18: ...16 Typical Installation Drawings Figure 19 Twin Tank Multiple Tank ...
Страница 62: ...60 ...
Страница 63: ... Copyright 2007 General Electric Company Printed in USA P N 3020015 Rev A ...