12
Magnum General Specifications
Operating and Environmental
Dynamic Pressure ................................................................................................................................................. 25 to 100 psig (172 to 688 kPa)
100 psig (688kPa) maximum in Canada
Operating Water Temperature Range.......................................................................................................................... 34 to 100
o
F (1 to 36
o
C)
Ambient Temperature Range............................................................................................................................................ 34 to 120
o
F (1 to 50
o
C)
Cap Bolt Torque ............................................................................................................................................... 35 to 40 inch lbs. (3.95 to 4.51 N
m
)
Connections
Inlet and Outlet ................................................................................................................................................................................. 2-inch Magnum IT
Tank....................................................................................................................................................................................................................... 4-inch 8UN
Brine...................................................................................................................................................................................................................3/4-inch NPT
Pilot Drain and Auxiliary Hydraulic Out .............................................................................................................................1/4-inch tube fitting
Riser Pipe Fitting............................................................................................................................................................................1-1/2 inch (3.81-cm)
Drain ...................................................................................................................................................................................................1-1/2 inch (3.81-cm)
Physical
Dimensions ...................................................................................................................................................26-11/16" L, 16-1/4" W, 10-11/16" H
Approximate Weight (Valve and Control) ................................................................................................................................23.3 lbs. (10.6 kg.)
Electrical*
Voltage - Logix 764 Series Control..................................................................................................... 12 VAC wall mount transformer only
Power Consumption...............................................................................................................................................................................................4 watts
*See section on Electronic Controls for alternative electrical configurations.
Содержание Logix 764
Страница 2: ......
Страница 18: ...16 Typical Installation Drawings Figure 19 Twin Tank Multiple Tank ...
Страница 62: ...60 ...
Страница 63: ... Copyright 2007 General Electric Company Printed in USA P N 3020015 Rev A ...