Programming the Lockout Feature
All Level I parameters can be locked out when the control
is in Level ll programming. Simply press the REGEN button
during Level ll programming and a Lock Icon will appear
indicating that the specific setting has been locked out.
When locked out, the setting cannot be adjusted. To
disable the Lock Out Feature, press the REGEN button
when in Level ll. The lock icon will not be displayed.
Salt Setting (298 Conditioner)
The default P6 salt setting is set at 9 lbs/cu ft. Under
normal circumstances this setting will provide the correct
system capacity. This setting may be adjusted to change
the exchange capacity.
Table 3 Standard Efficiency Exchange Capacity
Salt
lbs/cu ft
Exchange
Capacity
grains/cu ft
Salt
grams/
liter
Exchange
Capacity
grams/
liter
3
12714
50
29.9
4
15495
60
34.0
5
17774
70
37.5
6
19661
80
40.6
7
21250
90
43.4
8
22618
100
45.9
9
23828
110
48.2
10
24930
120
50.2
11
25962
130
52.1
12
26950
140
53.8
13
27916
150
55.5
14
28873
170
58.5
15
29829
200
62.7
16
30796
230
66.9
17
31783
260
71.0
18
32806
290
75.3