SensorCaution OFF Sensor Caution alarm turned off
SensorCaution ON Sensor Caution alarm turned on
RTC Bad
Real-time clock has failed
SensTstAlr Ack
Sensor fail alarm has been acknowledged
SetupLost Ack
Setup lost alarm has been acknowledged
SetupLost OFF
Setup lost alarm turned off
Set-up Lost ON
Setup lost alarm turned on
Soft WatchDog
Reset of Hydran M2-X induced by the software watchdog
Sp Span chg
Modification of the sensor temperature set point’s range
STempAlr Ack
Sensor temperature fail alarm has been acknowledged
STempAlr H chg
Modification of the sensor temperature High alarm’s set
point
STempAlr H ON
Sensor temperature High alarm turned on
STempAlr HH chg
Modification of the sensor temperature High-
High alarm’s set
point
STempAlr HH ON
Sensor temperature High-High alarm turned on
STempAlr L chg
Modification of the sensor temperature Low alarm’s set point
STempAlr L ON
Sensor temperature Low alarm turned on
STempAlr LL chg
Modification of the sensor temperature Low-
Low alarm’s set
point
STempAlr LL ON
Sensor temperature Low-Low alarm turned on
STempDelay chg
Modification of the sensor temperature alarm’s delay
STemp H OFF
Sensor temperature High alarm turned off
STemp HH OFF
Sensor temperature High-High alarm turned off
STemp L OFF
Sensor temperature Low alarm turned off
STemp LL OFF
Sensor temperature Low-Low alarm turned off
STempSetP chg
Modification of the sensor temperature set point
SystemCalib
Calibration of Hydran M2-X
TDM Mode chg
Modification of the TDM signal’s operating mode
Unit in Service
Hydran M2-X back in service after the battery was
disconnected
Watchdog
Reset of Hydran M2-X induced by the hardware watchdog