Installation Instructions
7
MOUNTING SYSTEM INSTALLATION
Pick a location under the sink to mount the system. Location should be easily accessible, with 4” of clearance
between the bottom of the filter canisters and the floor or bottom of the cabinet; any less will result in difficulty of
removing filter canisters (see Fig. 5). Allow enough space on either side of the system for the tubing connections.
System should be mounted at least 7” from front of cabinet to allow proper routing of tubing.
SCREW INSTALLATION
1.
Remove the top cover of system.
2.
Screws should be placed a minimum of 15 inches above the bottom
of the cabinet or floor where the system is to be mounted (Fig. 5).
NOTE: Any distance lower may result in filter canisters interfering
with the floor when removed.
3.
Use the system as a template to mark screw hole locations where
the screws are to be installed. Install screws into the wall, leaving
3/16 inch clearance between the head of the screw and wall (drill
pilot holes if needed) (Fig. 6). Use anchors if mounting to drywall.
Anchors require a 1/4” hole.
4.
Hang system on screws and tighten until system is held firmly.
5.
Install top cover onto system.
6.
Install 4 foot long yellow tube into inlet (left side) of system (inlet and outlet are labeled on top of the system).
7.
Install 4 foot long blue tube into outlet (right side) of system. Pull firmly on tubes to make sure they are secure.
8.
Remove shrink wrap from filters and install in system by turning approximately 1/3 turn until locked into place.
Filter will raise up as it is turned. Filter label will be centered and facing forward when fully installed.
NOTE: System may exhibit low flow or no flow at all if the filter is not fully installed.
9.
Turn on water supply valve and check for leaks.
10.
Perform Flush Procedure as described on page 8, steps 3-7.
15 inches
Screws
Screw
3/16 inch
Fig. 6
Fig. 5
Wall
System
Top Cover