– 2 –
G
R
O
U
N
D
20 TOP MOUNT GE™
DISCONNECT POWER CORD BEFORE SERVICING
Technical Data
IMPORTANT SAFETY NOTICE
238C4518P001
IMPORTANT - RECONNECT ALL GROUNDING DEVICES
All parts of this appliance capable of conducting electrical cur-
rent are grounded. If grounding wires, screws, straps, clips, nuts
or washers used to complete a path to ground are removed
for service, they must be returned to their original position and
properly fastened.
ELECTRICAL SPECIFICATIONS
Temperature Control (Position FF/FZ) ...................................................37/0°F
Defrost Control (w/no door openings) ............................. 10hrs @ 35 min
Overtemperature Thermostat .............................................................. 63-57°F
Electrical Rating: 115V AC 60 Hz .....................................................11.6 Amp
Maximum Current Leakage .................................................................. 0.75 mA
Maximum Ground Path Resistance ............................................. 0.14 Ohms
NO LOAD PERFORMANCE
Control Position 5/5 and Ambient of 70°F to 90°F
Fresh Food, °F ............................................................................................ 34 to 40
Frozen Food, °F ............................................................................................. -3 to 3F
Run Time, % @ 70°F .................................................................................. 20 to 40
Run Time, % @ 90°F .................................................................................. 40 to 70
This information is intended for use by individuals possessing
adequate backgrounds of electrical, electronic and mechanical
experience. Any attempt to repair a major appliance may result
in personal injury and property damage. The manufacturer or
seller cannot be responsible for the interpretation of this informa-
tion, nor can it assume any liability in connection with its use.
REFRIGERATION SYSTEM
Compressor ........................................................................................... 700 BTU/hr
Minimum Compressor Capacity .............................................. 22 inches Hg
Minimum Equalized Pressure
@ 70°F ................................................................................................. 40 to 45
PSIG
@ 90°F ................................................................................................. 48 to 60
PSIG
REFRIGERANT CHARGE (R134a)
20 TMNF models ................................................................................ 4.00 ounces
AIR FLOW
EVAPORATOR
COLD AIR
MIXED AIR
AIR RETURN TO
FREEZER
.105”
TO CABINET
WIRING
ORANGE
BLACK
GREEN/YELLOW
EVAPORATOR
FRESH FOOD
COMPRESSOR
REV. 0
Содержание GTRC0 Series
Страница 2: ......
Страница 5: ... 3 ...
Страница 7: ... 5 MODEL NOMENCLATURE Model series GTRS0 GTRC0 GTRL0 MTRL0 20 cubic foot refrigerators ...
Страница 11: ... 9 ...
Страница 12: ... 10 SERVICE REVIEW REMOVE DOORS TOP HINGE WITH 5 16 SOCKET SCREWDRIVER REMOVE TWO NUTS REMOVE THE TOP HINGE ...
Страница 14: ... 12 REMOVE FRESH FOOD DOOR LOWER HINGE WITH 5 16 SOCKET SCREWDRIVER REMOVE TWO NUTS ...
Страница 34: ... 20 EXPLODED VIEWS Knob Electro mechanical EX PL OD ED VIE WS ...
Страница 35: ... 21 Knob Electronic ...
Страница 36: ... 22 structure ...
Страница 37: ... 23 FREEZER DOOR FRESHFOOD DOOR ...
Страница 38: ... 24 HINGE ...
Страница 39: ... 25 RACKS SPILLPROOF ...
Страница 51: ... 37 Schematic Knob Electro mechanical ...
Страница 54: ... 40 COMPONENT AND CONNECTOR LOCATOR VIEWS ...
Страница 55: ... 41 Relay and Overload Under Cover Compressor Dryer No Clean Condenser Capacitor Condenser Fan ...