– 28 –
&DXWLRQ
The clamps are easily damaged during
removal and should not be reused.
12. Remove the 2 clamps, sump outlet hose, and
interconnect hose from the sump.
NOTE
: Factory installed hose clamps are not
reusable. When installing a water inlet valve, drain
the pump assembly, wash pump assembly, or sump
assembly, and replace the old clamps with new
screw-type hose clamps provided. The screw-type
hose clamps are available separately.
Clamp Part Number
Size
WD01X10322
15/16" to 1-1/2"
13. Remove the 2 Phillips head screws that hold the
drain pump to the sump.
14. Rotate the pump 1/4 turn counterclockwise to
remove.
Interconnect
Hose
Sump Outlet
Hose