– 22 –
Water Inlet Valve
The water inlet valve is electronically controlled and
VROHQRLGRSHUDWHG7KHÀRZRIZDWHULVFRQWUROOHG
E\DUXEEHUÀRZZDVKHUFDSDEOHRIPDLQWDLQLQJD
ÀRZUDWHRIJDOORQVSHUPLQXWH
liters per minute) with incoming water pressure
of 20 to 120 PSI. The water valve is mounted on a
bracket located on the left side of the front brace.
The water valve has an approximate resistance
value of 1k ohms and is energized for
approximately
VHFRQGVGXULQJHDFK¿OO
Operation of the water valve can be checked by
using the service mode. (See
Service Mode
.)
Water Valve Removal
1. Disconnect
power.
2. Remove the outer door panel (see
Outer Door
Panel Removal
).
3. Remove the 2 Phillips head screws, washers,
and the access panel.
7. Remove the clamp and the outlet hose from the
valve.
4.
'LVFRQQHFWWKHZDWHUVXSSO\OLQHIURPWKH¿OO
valve inlet.
5. Remove the 2 Phillips head screws that hold the
bracket to the front brace.
6. Disconnect the 2 wires from the solenoid.
8. Remove the four 1/4 in. hex head screws and
WKH¿OOYDOYHIURPWKHEUDFNHW
127(
Ensure the O-ring is retained in the valve
upon reassembly.
&DXWLRQ
The clamp is easily damaged during
removal and should not be reused. Use the screw-
type hose clamp provided with the new valve.
Disconnect
Bracket
Inlet
Outlet Hose
Clamp
O-Ring