Section 19 - Appendix B–Filter Board Options PWA 79562-01 and PWA 105521-01
71
5. Convert
M
to the closest 8 bit binary integer
M0
to
M7
.
6. Set the anti-aliasing filter corner frequency,
f
AA
.
Install/Remove jumpers for the multiplier value
M
and constant
K
, according to the
following table. The jumpers corresponding to values
M0
to
M7
are installed
according to these rules:
an installed jumper = 0,
M0 is the least significant bit
(LSB)
a removed jumper = 1,
M7 is the most significant bit
(MSB)
FILTER BOARD
ANTI-ALIASING CORNER FREQUENCY JUMPER TABLE
CHANNEL
K = 19.188
REMOVE
K = 268.9
INSTALL
(MSB) (LSB)
M7 M6 M5 M4 M3 M2 M1 M0
A
W43 W54 W43 W54 W55 W53 W52 W51 W50 W49 W48 W47
B
W56 W57 W56 W57 W77 W75 W74 W73 W72 W71 W70 W69