background image

The Hybrid Electric heat pump water heater is compatible 

with the 

GE Smart Appliance communication module 

(ACM

) which can be purchased separately. Contact 

your local utility or visit www.GEAppliances.com/

Smart-

Appliance

 to see if your area is using 

ACM

 technology. 

Applying the ACM allows the unit to respond to utility 

signals or to join a home network.
The following demand response features may be available  

as part of a pilot test program with the local utility 

company to help consumers reduce peak electricity  

usage in the home.

INSTALLATION

The ACM module is equipped with magnets in the base  

of the module that will enable it to be attached to the 

painted metal exterior of the heat pump water heater.
Details on how to connect the cables to the module are  

in the instructions that come with the module.

Once the cable from the ACM module is plugged into the 

water heater’s connection, follow the power-up directions 

included with the ACM module. As soon as the ACM 

module is operating, the heat pump water heater is ready 

to receive the ACM signals.

QUICK GUIDE

If your local utility company is utilizing ACM technology, 

the ACM module will receive the signals sent from your 

utility company. One of four signals will be sent: 
• “Low” (represents lowest energy cost rate is available) 
• “Medium” (represents increased energy cost rate)
• “High” (represents increased energy cost rate)
• “Critical”(represents “peak rate” energy cost rate)
 A heat pump water heater equipped with a ACM module 

will automatically recognize what energy cost rate is 

available and adjust its mode and temperature setting to 

use less energy when rates are medium, high and critical. 

When the heat pump water heater responds to these 

signals, the LED light above the Power Saver button will be 

on, indicating energy pricing periods are in effect, and the 

letters PS will be displayed on the LED if the user attempts 

to change the temperature without first pressing the 

Power Saver override button.
When the signal is low or when no ACM module is 

connected, the unit runs as normal. The following steps 

show how the unit reacts to Medium, High and Critical 

signal levels.

When the ACM signal is 

Medium

, the control will operate 

in Heat Pump (only) Mode and the water temperature will 

remain at the current user setting. The screen will display 

the following (where xxx is the current user temperature 

setting):

 

When the ACM signal is 

High

, the control will operate in 

Heat Pump (only) mode, with a water temperature setting 

of 110°F (43°C), and the screen will display: 

When the ACM signal is 

Critical

, the control will operate in 

Heat Pump (only) mode, with a water temperature setting 

of 100°F (38°C), and the screen will display:

Notice:   

Appliance ACM connection carries voltage not 

compatible to computers or accessories.  Do NOT plug 

laptops, modems, routers, etc into the Appliance RJ45 

ACM connector.  Use only with designated GE Appliance 

Accessories.  Connection to computers and accessories 

may result in product damage.
When unit is operating in medium, high or critical, the LCD 

above the Power Saver button will be lit.  If at any time you 

want to change the temperature setpoint while the unit is in 

Power Saver mode, press and hold the Power Saver button to 

override the Power Saver mode, then use the arrow buttons 

to change to the desired setting.  Override will be in place 

for 18 hours.  If you try to change the temperature without 

overriding the powersaver function, the letters PS will show on 

the display, indicating it is still in Powersaver mode.

XXX

F

C

D

AYS

Appliance Communication Module 

(where installed)

 

 

10

110

F

C

D

AYS

100

F

C

D

AYS

ACM module

ACM connector

Содержание Appliances Geospring GEH50DEEDXX

Страница 1: ...Consumer Support 50 Write the model and serial numbers here Model _ ________________ Serial __________________ You can find them on the rating label on the front side of your water heater GeoSpring Hy...

Страница 2: ...from scalding Be sure to read and follow the warnings outlined on the label pictured below This label is also located on the water heater near the top of the tank Time Temperature Relationship in Sca...

Страница 3: ...use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Keep rags and other combustibles away FOR INSTALLATIONS IN THE STATE OF CALIFORNIA California Law req...

Страница 4: ...TCO breaks the power circuit to the heating element Once the control opens it must be reset manually Resetting of the temperature limiting controls should be done by a qualified service technician CA...

Страница 5: ...d Filter is located on top of the water heater Press button and hold for 5 seconds to reset filter alarm Power Saver Override For use with ACM module Press and hold to bring unit out of Power Saver mo...

Страница 6: ...recommended that the unit be set to Heat Pump only mode to maximize energy savings Operating in Hybrid mode provides a balance of energy savings and hot water use convenience Reported energy consumpti...

Страница 7: ...ter heater near the upper element access panel See Time Temperature Relationship in Scalds below as a guide in determining the proper water temperature for your home Mixing valves Mixing valves for re...

Страница 8: ...and use the heat pump when water demand rates are lower NOTE The difference between Hybrid mode and High Demand mode is that in High Demand mode the heating resistive elements are activated sooner tha...

Страница 9: ...efficient Heat Pump the majority of the time Q What is Vacation mode A If you are gone for an extended period this mode lowers the water temperature to reduce energy used Unit will switch to the prev...

Страница 10: ...he LED light above the Power Saver button will be on indicating energy pricing periods are in effect and the letters PS will be displayed on the LED if the user attempts to change the temperature with...

Страница 11: ...be released into a suitable drain to prevent injury or property damage NOTE If the temperature and pressure relief valve on the hot water heater discharges periodically this may be due to thermal exp...

Страница 12: ...revert to the mode it was in prior to being switched IMPORTANT Filter must be cleaned when the alarm is displayed A dirty filter will make the system work harder and result in a reduction of efficien...

Страница 13: ...available from some local libraries or can be purchased from the National Fire Prevention Association Batterymarch park Quincy MA 02169 as booklet ANSI NFPA 70 Power requirements Check the markings on...

Страница 14: ...o the illustration on page 15 The expansion tank is designed with an air cushion built in that compresses as the system pressure increases thereby relieving the over pressure condition and eliminating...

Страница 15: ...ge line CAUTION To reduce the risk of excessive pressures and temperatures in this water heater install temperature and pressure protective equipment required by local codes and no less than a combina...

Страница 16: ...heater and the electrical distribution box To connect power to the water heater 1 Turn the power off 2 Remove the screw screws holding the junction box top cover 3 Install L1 to L1 L2 to L2 and groun...

Страница 17: ...his water heater will require careful attention to the following Do not cover the temperature and pressure relief valve Do not cover access panels to the heating elements Do not cover the electrical j...

Страница 18: ...In Hybrid mode After the unit has been installed with all electrical and water connections secure and checked then the unit should be filled with water vent tank by opening a hot water faucet somewhe...

Страница 19: ...de Water usage may have Wait for the water heater to recover after an abnormal exceeded the capacity demand of the water heater Ambient temperature is For the water heater to work properly its locatio...

Страница 20: ...re you continue to have hot water Contact FA F8 service immediately and give them the codes listed on the display screen The heater is beeping There is an issue with the The heater may switch to anoth...

Страница 21: ...et temperature Failure Call service F 6 T3b Sensor Evap outlet temperature Failure Call service F 7 T4 Sensor Compressor outlet Failure Call service F 8 T5 Sensor ambient temperature Failure Call serv...

Страница 22: ...s located in an area where service by a GE Authorized Servicer is not available you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service locatio...

Страница 23: ...Notes GEAppliances com 23...

Страница 24: ...Notes 24...

Страница 25: ...x questions FAQ 33 Module de communication de l appareil ACM 34 Entretien et nettoyage 35 36 Instructions d Installation 37 42 Conseils de D pannage 43 45 Service la client le 48 Inscrivez les num ros...

Страница 26: ...e 52 C 125 F peut causer des br lures graves ou la mort par bouillantage Assurez vous de lire et de suivre les avertissements expos s sous l image de l tiquette ci dessous Cette tiquette est galement...

Страница 27: ...ie exigent que les chauffe eau r sidentiels soient fix s ancr s ou attach s pour qu ils ne tombent pas et qu ils r sistent aux mouvements horizontaux caus s par les tremblements de terre Pour les chau...

Страница 28: ...pour accomplir le travail Pr cautions de s curit Le chauffe eau est quip de deux commandes de limitation de temp rature CLT qui sont situ es au dessus de l l ment chauffant en contact avec la surface...

Страница 29: ...tialiser l alarme de filtre Interrupteur de fonction d conomie d nergie Pour une utilisation avec le module MCA Appuyez sur cette touche et maintenez la enfonc e pour sortir l appareil du mode conomie...

Страница 30: ...eil soit mis sur le mode Thermopompe uniquement pour favoriser les conomies d nergie Le fonctionnement en mode hybride permet d quilibrer les conomies d nergie avec le confort de l eau chaude La conso...

Страница 31: ...l g rement sup rieures peuvent tre atteintes Consultez le paragraphe R glage de la temp rature ci dessous pour modifier la temp rature de l eau Capacit en eau chaude Si vous souhaitez obtenir une plu...

Страница 32: ...saire La thermopompe sera utilis e si la demande en eau est plus faible REMARQUE La diff rence entre le mode Hybride et le mode Demande lev e est que dans le mode Demande lev e les l ments chauffants...

Страница 33: ...ppareil continuera d utiliser la thermopompe la plupart du temps Q Qu est ce que le mode de Vacances A Si vous tes absent pendant une p riode prolong e ce mode r duit la temp rature de l eau pour r du...

Страница 34: ...en vigueur Les lettres PS s affichent si l utilisateur essaie de modifier la temp rature sans avoir appuy sur le bouton pour d sactiver la fonction conomie d nergie Lorsque le signal est faible ou lor...

Страница 35: ...assez chaude pour cr er un risque de br lure L eau doit tre envoy e vers une bonde de vidange pour viter toutes blessures ou tous dommages mat riels REMARQUE Si une soupape de s curit du chauffe eau...

Страница 36: ...ement au mode pr c dent le nettoyage du filtre IMPORTANT Le filtre doit tre nettoy lorsque l alarme s affiche Un filtre sale rend plus difficile le travail du syst me et peut entra ner une r duction d...

Страница 37: ...ionale de la pr vention d incendie Batterymarch park Quincy MA 02169 USA comme feuillet ANSI NFPA 70 EXIGENCES EN MATI RE D ALIMENTATION ELECTRIQUE Check the markings on the rating plate of the water...

Страница 38: ...ion du syst me liminant ainsi la surpression et le fonctionnement continu de la soupape D autres m thodes de contr le d expansion thermique sont galement disponibles Contactez votre installateur fourn...

Страница 39: ...chauffe eau installez l quipement de protection de temp rature et de pression exig par les codes municipaux et au moins une soupape de s curit pression et temp rature certifi e par un laboratoire d e...

Страница 40: ...la bo te de distribution lectrique Branchement de l alimentation lectrique au chauffe eau 1 Coupez l alimentation 2 Retirez le s vis maintenant le couvercle de la bo te de jonction 3 Fixez L1 L1 L2 L2...

Страница 41: ...ctu e en portant une attention particuli re aux points suivants Ne couvrez pas la soupape de s curit temp rature et pression Ne couvrez pas les panneaux d acc s aux l ments chauffants Ne couvrez pas l...

Страница 42: ...l et apr s que tous les branchements lectriques et de plomberie aient t effectu s et v rifi s l appareil doit tre rempli d eau vacuez l air du r servoir en ouvrant un robinet d eau chaude quelque part...

Страница 43: ...ue le chauffe eau r tablisse la temp rature apr s peut d passer la capacit du une demande anormalement lev e chauffe eau La temp rature ambiante est Pour que le chauffe eau puisse fonctionner correcte...

Страница 44: ...ce apr s vente pour leur donner les codes affich s l cran Le chauffe eau met un Il y a un probl me avec le Le chauffe eau passera peut tre un autre mode de signal sonore et l cran chauffe eau qui exig...

Страница 45: ...ez un technicien F 6 Panne du capteur T3b temp rature d entr e de l vaporateur Appelez un technicien F 7 Panne du capteur T4 sortie du compresseur Appelez un technicien F 8 Panne du capteur T5 temp ra...

Страница 46: ...vice de mat riau ou de main partir de la date d uvre Pendant la validit de la pr sente garantie limit e d un an GE fournira galement gratuitement d achat initiale la main d uvre et le service sur plac...

Страница 47: ...47 Notes Www electromenagersge ca...

Страница 48: ...48 Notes Www electromenagersge ca...

Страница 49: ...res directement la maison cartes VISA MasterCard et Discover accept es Les directives stipul es dans le pr sent manuel peuvent tre effectu es par n importe quel utilisateur Les autres r parations doiv...

Страница 50: ...ness hours GE Consumer Home Services will still be there after your warranty expires In Canada contact your extended warranty provider Extended Warranties In the U S GEAppliances com Individuals quali...

Отзывы: