Appendix A: Troubleshooting
32
Panel displays TEL MODULE VERSION ERROR.
The DTIM’s software may not be compatible with the panel’s software.
1.
Contact technical support for assistance.
Phone
Constant dial tone, preventing dial-out on premises phones.
One or more polarity-sensitive phones exist on-site.
Panel displays
phone 1 fail, phone 2 fail, or phone failure
.
1.
Check DTIM wiring (see DTIM installation instructions).
2.
There may be a problem with the central station.
Phone Test
Panel does not display option to perform a phone test.
• The central station phone number is not programmed in.
• DTIM has not been enrolled.
• Phone test option is off.
Alarm report is not called into central station.
1.
Perform a phone test.
2.
Check to make sure the phone test option is on.
3.
Verify that high and/or low level reporting option is on.
4.
Perform a sensor test to verify communication between the DTIM and panel. See “Phone Test
(2nd Tier)” on page 23
Downloader
Download/upload session fails on a pre-programmed panel.
1.
Verify Downloader Phone Number matches ToolBox setting.
2.
Verify Downloader CODE matches ToolBox setting.
3.
Verify Dealer CODE matches ToolBox setting.
4.
Verify panel Account Number matches ToolBox setting.
Download/upload session fails on an unprogrammed panel.
1.
Verify Downloader Phone Number matches ToolBox setting.
2.
Verify Downloader CODE matches ToolBox setting.
3.
Verify Dealer CODE matches ToolBox setting.
Receiver
Panel displays RX JAM.
There may be a “runaway” transmitter - a transmitter that is constantly transmitting.
1.
Use an RF Sniffer to identify the runaway transmitter. Place the RF Sniffer next to each RF sen-
sor until you find the sensor that is transmitting.
2.
Remove the battery from the sensor.
3.
Replace the sensor.
Panel displays RX FAILURE.
The panel has not heard an RF signal for 4 hours.
1.
Contact technical support for assistance.
Feature Problem
Action/Solution