Installer Programming Menus
11
Note
When installing Crystal sen-
sors and encrypted keychain
touchpads, use the installa-
tion instructions included
with the sensor.
Sound
17
Glassguard
17
Smoke
26
Rate of Rise
26
DTIM
39
Table 2: Sensor Group Assigned to Device
Device
Sensor Group
Table 3: Device Programming
Device
To Program
Door/Window Sensor (SAW)
Press button on top of sensor (cover removed).
Motion Sensor
Press and release the button on back of sensor (mounting
plate removed).
Keychain Touchpad (non encrypted)
Press lock & unlock buttons until LED blinks.
Keychain Touchpad (encrypted)
See Note.
Crystal Sensors
See Note.
DTIM
3-2-1 sequence (page 6).
Hardwire Sensor
For normally closed - separate sensor from magnet.
For normally opened - close sensor then reopen.
Carbon Monoxide Alarm
Plug in the module and within 30 seconds, press and hold
the TEST/RESET button until you hear 6 beeps.
ADD
(2nd Tier)
(DEVICES—)
Note
To override the preassigned
sensor number, use the arrow
keys to skip to the desired sen-
sor number.
(Default = None)
When adding devices, the panel will automatically assign the device to a sensor group based on
the type of device. Table 2 outlines the sensor group assigned to each device.
¾
To add a device:
1. Press
#
. The display shows
ZONE
{01- 20} -
TRIP
.
2. Trip the sensor (see Table 3). The panel beeps twice to indicate the sensor was successfully
learned into the panel.
3. Repeat step 2 until all desired zones are added.
DELETE
(2nd Tier)
(DEVICES—)
Note
Deleting zones/sensors does
not delete text associated with
the deleted zone/sensor num-
ber.
(Default = None)
The following procedure describes how to remove hardwire and wireless sensors from panel
memory.
¾
To delete a device:
1. To select a different zone press
to scroll through the learned zones. Press
#
to delete the
displayed zone. The display shows the next sensor.
2. Repeat step 1 until all desired zones are deleted.
Содержание Allegro
Страница 6: ...iv ...