Installer Programming Menus
9
LOW LVL
(3rd Tier)
(PHONES—PHONE1 & PHONE 2—)
(Default = Phone 1: on, Phone 2: off, UL installations = On)
When this setting is on, the following non-alarm conditions report to the central station:
•
AC Failure
•
Forced Arming
•
Entering or Exiting Sensor Test Mode
•
Hardwire Zone Trouble
•
RF Supervisory
•
RF Low Battery
•
Low Panel Battery
•
Phone Test
¾
To turn Low Level reports on or off under Phone 1/2:
Press
#
to turn it on or off.
OPENINGS
(3rd Tier)
(PHONES—PHONE 1 & PHONE 2—)
(Default = Off)
This setting determines whether an opening report is sent to the central station. When turned
on, the panel sends an opening report when the system is disarmed.
¾
To turn Openings reports on or off under Phone 1 or 2:
Press
#
to turn it on or off.
CLOSINGS
(3rd Tier)
(PHONES—PHONE 1 & PHONE 2—)
(Default = Off)
This setting determines whether a closing report is sent to the central station. When turned on,
the panel sends a closing report when the system is armed.
¾
To turn Closings reports on or off under Phone 1 or 2:
Press
#
to turn it on or off.
BACKUP
(3rd Tier)
(PHONES—PHONE 2—)
(Default = On)
This setting determines whether the DTIM uses phone number 2 for reporting if three initial
attempts on phone number 1 are unsuccessful.
PHONE
1
is backed up by
PHONE
2
. The DTIM
makes up to 16 attempts (8 per phone number), alternating between the two programmed
phone numbers.
For example, if Backup is on and three failed reporting attempts occur using
PHONE
1
, (panel
displays
PHONE
1
FAIL
), the DTIM switches to
PHONE
2
for three more reporting attempts. If
these attempts fail, (panel displays
PHONE
2
FAIL
), the DTIM switches back to
PHONE
1
for five
more reporting attempts and, if necessary, switches back to
PHONE
2
for five final attempts. If
these final attempts fail, the panel will display
PHONE
FAILURE
.
¾
To turn Backup on or off:
Press
#
to turn it on or off.
Содержание Allegro
Страница 6: ...iv ...