Chapter 2
Alliance system menu
41
System menu option 12, Test zone
Use this menu to test if an individual zone is operating correctly.
Note:
The test must be carried out within a predetermined time. If the test is not completed within this time, the option is
exited.
Test a zone
To test a zone, do the following:
1. Press
MENU*
(
Figure 1
)
,
enter your user
PIN code, and press
ENTER
(
Figure 1
).
2. Enter
12
(for menu 12) and press
ENTER
.
The display shows the test a zone window
(
Figure 45
).
Note:
If the zone is bypassed when a test is
requested, the system unbypasses the
zone, conducts the test, then returns the
zone to bypassed.
Figure 45. Test a zone
3. Enter the zone number for one of the
following four responses and press
ENTER
.
3a. The zone is normal (
Figure 46
).
Figure 46. Normal test zone
3b. The zone is active (
Figure 47
).
Figure 47. Active test zone
3c. There is a faulty condition due to cable
tamper. The cabling to the zone shows an
OPEN circuit (
Figure 48
).
Figure 48. Cable tampering, open
Test Individual Zone:
Zone No:
NORMAL STATE on 12, Roller Door
Press ENTER
ACTIVE on 12, Roller Door
Press ENTER
OPEN on 12, Roller Door
Press ENTER