Alliance System
User Manual
18
What to do when an alarm occurs
When there is an alarm, the area in alarm LED flashes red on the keypad. The time and date message is no
longer displayed. An area can have several zones associated with it. When there is an alarm, it is important that
you know which zone is causing the problem so that you can quickly locate and fix it.
Resetting a local alarm
The keypad emits a modulating tone until the local alarm is acknowledged (if programmed).
The LED of the area in alarm flashes red on the keypad (if programmed).
The display shows:
Table 7
lists the display options.
Local alarms for certain zone types can only be acknowledged by entering
USER CODE+ OFF+AREA+
ENTER
. These are:
•
21 Day/night with user code.
•
30 Day/night with auto reset.
•
42 Entry/exit fire door with code.
•
44 Day/night with alarm group restriction.
•
56 Day/night if no time zone 41.
Table 7.
RAS keypad actions for local alarms
Option
Action
Acknowledge the local alarm (see note below). Depending on
programming, a user code may be required to reset.
Enter
0
and press
ENTER
(
Figure 1
)
.
Display the complete zone name.
Enter the zone number and press
ENTER
.
Update the list of zones and display the next zone on the list (if
any).
Press
ON/NEXT
(see
Figure 1
)
.
Exit the menu option and return to the original display.
Press
CLEAR
(see
Figure 1
)
.
,Alarm On …
Code: