– 42 –
2.
Remove outer case.
3.
Remove the complete control panel as-
sembly.
4.
Remove the upper halogen blower/lamp
assembly.
5.
Remove the 6 screws securing the relay
board/air guide cover assembly to the
oven chassis (see illustration below).
6.
Swing the relay board/air guide assembly
away from the unit so that you can ac-
cess the magnetron blower assembly.
7.
Remove the wiring connector plug from
the magnetron blower motor and remove
all associated wiring from the magnetron
blower housing (see illustration to the up-
per right). Important note: Be sure to
note the location and routing of wires for
proper reinstallation purposes.
8.
Remove one screw securing the magne-
tron blower assembly to the oven chas-
sis, (see illustration below), and remove
the blower assembly.
DAMPER DOOR ASSEMBLY - REMOVAL
To remove the damper door assembly, follow
these steps:
1.
Remove the oven from the wall plate
2.
Remove the outer case
RELAY BOARD/AIR GUIDE
COVER ASSEMBLY REMOVED
B
A
A
A
B
B
MAGNETRON
BLOWER ASSY
HIGH VOLTAGE WIRE:
RED WIRE W/ BLACK STRIPS
LOWER HALOGEN BLOWER/MAG.
MOTOR WIRING HARNESS
HIGH VOLTAGE WIRES:
RED WIRE W/BLACK
STRIPES PLUS WHITE
WIRE
Содержание Advantium SCA2000BCC