– 4 –
Mounting Space
This section describes the space you need to install
your oven.
Your oven requires mounting space on a wall
as shown.
1. A minimum of 30
″
between the cabinets is
required for installation. If the space between
the cabinets is greater than 30
″
, a Filler Panel
Kit may be used to fill in the gap between the
oven and the cabinets. Your Owner's Manual
contains the kit number for your model.
2. Make sure the bottom edge of the cabinet that
will be above the oven is at least 66
″
from the
floor and 30
″
from the cooking surface.
3. For easier access to change the hood and range
lamps, the bottom of the oven should be at least
2
″
above the range backsplash.
4. If you are going to vent your oven to the outside,
see Section 5 for exhaust duct preparation.
5. When installing the oven beneath smooth,
flat cabinets, be careful to follow the
instructions on the top cabinet template for
power cord clearance.
6. For best installation results, we recommend a
maximum cabinet depth of 12
″
.
Electrical Requirements
Product rating is 240/208 volts AC, 60 Hertz,
30 amps and 6.5 kilowatts. This product must be
connected to an individual properly grounded
branch circuit, protected by circuit breakers or
time delay fuses. Wire size must conform to the
requirements of the National Electric Code or the
prevailing local code for this kilowatt rating. The
outlet box should be located in the cabinet above
the oven. The supply circuit and outlet box should
be installed by a qualified electrician and conform
to all prevailing electrical codes. The wall outlet
receptacle recommended for this appliance is
NEMA # 14-30R and accepts the four prong
grounded plug of this appliance (see Fig. 1 above).
IMPORTANT – PLEASE READ CAREFULLY.
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED TO
AVOID SEVERE OR FATAL SHOCK.
DO NOT UNDER ANY CIRCUMSTANCES,
CUT, DEFORM, OR REMOVE ANY OF THE
PRONGS FROM THE POWER CORD. DO NOT
USE WITH AN EXTENSION CORD.
Insure proper
ground exists
before use.
NEMA 14-30R
Wall Receptacle
Fig. 1
REQUIREMENTS FOR INSTALLATION
Important Safety Instructions
See electrical requirements for proper outlet
installation and grounding of this appliance. The
installer must perform a ground continuity check
on the power outlet box before beginning the
installation to insure the outlet box is properly
grounded. If not properly grounded, or if the
outlet does not meet electrical requirements noted
below, a qualified electrician should be employed
to correct any deficiencies.
CAUTION: For personal safety, remove house
fuse or open the circuit breaker before
beginning installation.
CAUTION: For personal safety, the mounting
surface must be capable of supporting the
cabinet load in addition to the added weight
of this 70 lb. product plus oven loads of up
to 50 lbs., or a total of 120 lbs.
CAUTION: For personal safety, this product
cannot be installed in cabinet arrangements
such as an island or a peninsula. It must be
mounted to both a top cabinet and a wall.
NOTE: For easier installation and personal safety,
it is recommended that two persons install this
product.
1
Bottom Edge
of Cabinet
Needs to be
30
″
or More
From the
Cooking
Surface
Backsplash
66
″
or More
From the
Floor to the
Top of the
Oven
30
″
2
″
30
″
16-1/8
″
INSTALLATION INSTRUCTIONS
Содержание Advantium SCA2000BCC
Страница 53: ... 51 ...