MDS 05-2708A01, Rev. F
MDS TransNET Ref. Manual
27
REPEAT
The fixed downstream re-send count.
RETRY
The maximum upstream re-send count for
ARQ (Automatic Repeat Request) operation.
RSSI
Received signal strength indicator (in dBm).
Unavailable at Master unless SETUP is
enabled.
RTU
RTU simulator’s operational status (ON/OFF)
RXTOT
The amount of time (in seconds) to wait before
issuing a time-out alarm.
SAF
Store-and-forward mode status in this unit.
(ON/OFF)
SER
Serial number of radio
SHOW CON
Display virtual modem connection status
SHOW PWR
RF output power.
Measured RF power in dBm.
SHOW SYNC
Information on synchronization source
SKIP
Frequency zones that are skipped
SLEEP
Radio’s Sleep Mode setting.
(At Remotes Only)
SREV
Transceiver firmware revision level
STAT
Current alarm status
TEMP
Transceiver’s internal temperature (°C)
UNIT
Programmed unit address for
network-wide diagnostics
XADDR
This unit’s Extended address
Table 10. Operating Status—Display Only (Continued)
Command
Description