MDS TransNET Ref. Manual
MDS 05-2708A01, Rev. F
ASENSE
Current sense of the alarm output.
BAUD
Data communication parameters. Example:
BAUD 9600 8N1
BUFF
Data buffering mode: ON = seamless data,
OFF = fast byte throughput
CODE
Security/encryption operational status.
“NONE” (Inactive), or “ACTIVE”
CTS
CTS delay in milliseconds (0–255 ms)
CTSHOLD
“Hold time” that CTS is present following last
character from DATA port.
DEVICE
Device behavior
Alternatives: DCE and CTS KEY
HOPTIME
Hop-time value in milliseconds (ms).
LPMHOLD
Time (0-1000 ms) provided to give an RTU
time to respond before the radio goes to sleep.
MODE
Current operating mode:
M = Master
R = Remote
X = Extension (Repeater)
MRSSI
Minimum RSSI level required to preserve syn-
chronization with a Master radio for Remotes
in mobile service.
OWM
Owner’s message or site name
OT
Status (ON/OFF) of the 1-second delay on
delivery of RXD serial data.
OWN
Owner’s name or system name
PORT
Current data port (DATA connector) interface
signaling mode: RS232 or RS485
PWR
Forward power-output setting in dBm
Table 10. Operating Status—Display Only (Continued)
Command
Description