MDS 05-2708A01, Rev. F
MDS TransNET Ref. Manual
57
AT <command errors>
Replies with
ERROR
(Code 4)
Characters with <no AT command>
Modem will echo characters in data stream but will be ignored until a
second “AT” is seen at which time the modem closes the virtual
connection.
Operation Notes When AT Commands are ON
• Radios will not poll with the embedded RTU simulator unless a
connection is established.
• Network-wide diagnostics are unaffected by the dialed unit connection
status.
• The use of the TransNET
OT
command (Output Trigger) can be of
benefit in some configurations. See
configuration details.
9.4 Configuration Parameters for Store-and-Forward
Services
The installation and configuration of a radio network with an Extension using
SAF is straightforward with only a few unique parameters that need to be
considered and set at each unit.
In every network there can be only one Master station. It will serve as the sole
gateway to the outside world. The following three tables detail the parameters
that will need to be set on each type of radio in the network.
• Extension Radio(s)—
• Remote Radio(s)—
Table 21. Configuration Parameters for SAF Services
Network Master Radio
Parameter
Command
Description
Operating Mode
MODE M
Sets the radio to serve as
a Master.
Network Address
ADDR
A number between 1 and
65,000 that will serve as a
common network ad-
dress.
All radios in the network
use the same number.