MDS 05-2708A01, Rev. F
MDS TransNET Ref. Manual
43
A display of
06-4040A01, 3.6.1
is an example of the firmware version identi-
fier—part number followed by release/version number.
STAT
Alarm Status
This command is used to check the alarm status of the radio. If no alarms
exist, the message
NO ALARMS PRESENT
is returned.
If an alarm does exist, a two-digit alarm code (00–31) is displayed and the
event is identified as a “Major” or “Minor” alarm. A brief description of the
event is also given.
If more than one alarm exists, the word
MORE
appears, and additional alarms
may be viewed by pressing the
key. Detailed descriptions of the
.
TEMP
Radio’s Internal Temperature
This command displays the internal temperature of the transceiver in degrees
Celsius. (Note that the radio is specified to operate in an environment between
–30° C and +60° C). This internal reading may be higher than the outside
temperature by several degrees.
TX [xxxx]
Radio Transmit Test Frequency
This command sets or displays the test transmit frequency used in place of
hopping whenever the radio is in Setup mode. The test transmit frequency for
the 900 MHz radios can be reprogrammed to any value between 902.200
MHz and 927.800 MHz, inclusive. The factory default setting is 915.000
MHz.
For the 2400 MHz radios, the test frequency can be programmed to any
frequency between 2400.6 MHz and 2482.0 MHz. The default value is
2436.0 MHz.
UNIT [10000–65000]
Unit Address
This command sets the unit addressing for network-wide diagnostics and
AT-Command address. The unit address is factory programmed to the last
four digits of the radio’s serial number. If re-programmed in the field, the
entry must consist of five digits between 10000 and 65000.
ENTER