Appendix A: System Configuration Worksheets

58

019

Basement

059

Energy Saver 099

Kitchen

139

Pool

179

Unbypass

219

Y

020

Bathroom

060

Enter

100

Latchkey

140

Porch

180

Unit

220

Z

021

Battery

061

Entry

101

Laundry

141

Power

181

Up

221

(space)

022

Bedroom

062

Error

102

Left

142

Press

182

West

222

’(apostrophe)

023

Bottom

063

Exit

103

Level

143

Program

183

Window

223

 - (dash)

024

Breezeway

064

Exterior

104

Library

144

Progress

184

Zone

224

_ (underscore)

025

Building

065

Factory

105

Light

145

Quiet

185

0

225

 *

026

Bus

066

Failure

106

Lights

146

Rear

186

1

226

 #

027

Bypass

067

Family

107

Living

147

Receiver

187

2

227

:

028

Bypassed

068

Father’s

108

Load

148

Report

188

3

228

 /

029

Cabinet

069

Feature

109

Loading

149

RF

189

4

229

?

030

Canceled

070

Fence

110

Low

150

Right

190

5

031

Car

071

Fire

111

Lower

151

Room

191

6

032

Carbon 
Monoxide

072

First

112

Main

152

Safe

192

7

033

Central

073

Floor

113

Master

153

Schedule

193

8

034

Chime

074

Force

114

Mat

154

Screen

194

9

035

Closed

075

Foyer

115

Medical

155

Second

195

A

036

Closet

076

Freeze

116

Memory

156

Sensor

196

B

037

Closing

077

Front

117

Menu

157

Service

197

C

038

Code

078

Furnace

118

Mother’s

158

Shed

198

D

039

Computer

079

Gallery

119

Motion

159

Shock

199

E

040

Control

080

Garage

120

No

160

Side

200

F

Table A4: Item Numbers and Sensor Text (Continued)

Item # Sensor Text Item # Sensor Text Item #

Sensor 

Text

Item #

Sensor 

Text

Item # Sensor Text Item #

Sensor Text

Table A5: System Settings

Menu Name & (Default)

Shortcut No.

Setting

Installer Programming—8 + Installer/Dealer CODE + 00

24-Hour Tamper

05000

AC Failure (Off)

05010

Account No. (00000)

0010

Activity Timeout (24 hours)

0305

Alarm Verify (Off)

0516

Auto Phone Test (Off)

02001

Auto Stay Arming (On)

0014

Auto Test Reset (On)

02002

Auxiliary Panic (On)

0401

Back In Service (On)

05002

Backup (CS Phone 1 On, CS Phone 2 Off)

0104 - cs phone 1
0114 - cs phone 2

___________
___________

Battery Restoral (Off)

05005

Buffer Control (Off)

05001

Buffer Full Report (Off)

05006

Bypass Reports (Off)

05003

CS Phone 1 (None)

0100

CS Phone 2 (None)

0110

Call Wait Cancel (None)

02009

Содержание 60-806-95R-16Z - Security Concord Express System Control...

Страница 1: ...h d e l a y d o o r 2 3 1 P r e s s 2 C O D E C l o s e a l l p r o t e c t e d d o o r s a n d w i n d o w s P r e s s 4 t o a r m d e l a y d o o r s i n s t a n t l y A r m t o A W A Y Z o n e S e...

Страница 2: ...mpliant See the Installation Instructions for details Alarm dialing equipment must be able to seize the telephone line and place a call in an emergency situation It must be able to do this even if oth...

Страница 3: ...unication Le mat riel doit galement etre install en suivant une m thod accept e de raccordement Dans certains cas les fils int rieurs de l enterprise utilis s pour un service individuel a ligne unique...

Страница 4: ...12 Connecting Siren Drivers Self Contained Sirens and Bells 13 Connecting Touchpads 14 Installing an RJ 31X Phone Jack 13 081 14 Connecting the Phone Line to the Panel with a DB 8 Cord 15 Connecting...

Страница 5: ...lay LCD Touchpad Chime and Trouble Beep Tones 49 Troubleshooting 50 Appendix A System Configuration Worksheets 54 Cross Zoning 57 Appendix B Programming Mode Menus and Settings 66 Specifications 68 Wi...

Страница 6: ...y 12 VDC 4 AH 60 681 SuperBus 2000 2x16 LCD Touchpad 60 746 01 SuperBus 2000 Fixed Display Touchpad 60 820 SuperBus 2000 2x20 LCD Touchpad 60 803 or SuperBus 2000 2x20 VFD Touchpad 60 804 Standard Cla...

Страница 7: ...ts The following table describes programming requirements to meet ANSI SIA CP 01 The following table describes non programmable hard coded system operation as required to meet ANSI SIA CP 01 and is pr...

Страница 8: ...to power the panel Residential Burglary Alarm System Unit CAN ULC S309 Same as UL Basic System and Household Burglary Alarm System Unit UL 1023 described previously and siren timeout must be set to 5...

Страница 9: ...not installer or dealer programming Displays system messages and indi cates system status SnapCard The following SnapCards expand the system as described 8Z Input SnapCard Provides eight additional ha...

Страница 10: ...by a nonconductive barrier OR B Class 2 Class 3 and power limited fire alarm cir cuit conductors must be installed as Class 1 or higher circuits Table 1 describes panel voltage current output ranges...

Страница 11: ...ting Holes 5 Install anchors where studs are not present 6 Partially insert screws into the two top mounting hole locations then hang the panel on the two screws 7 Recheck for levelness insert the two...

Страница 12: ...es and making wiring connections familiarize yourself with the main components of the panel Figure 4 shows the main component locations on the circuit board Figure 4 Main Component Locations Connectin...

Страница 13: ...lace with two screws included with the card Figure 6 Connect all necessary input output wiring using the installation instructions included with the SnapCard Figure 6 Installing a SnapCard Note Use of...

Страница 14: ...Devices Figure 8 shows the typical wiring for N C and N O door window intrusion detection Figure 8 Connecting N C and N O Intrusion Detection Circuits Figure 9 shows the typical wiring for Optex mode...

Страница 15: ...t up for 2 wire smoke detectors zone 6 can handle up to 10 smoke detectors with 120 A maximum idle current per detector Maximum total loop current allowed in an alarm condi tion is 80 mA The maximum l...

Страница 16: ...01500 For more information on output configuration numbers see the section Programming the Panel and the tables in Appendix A Use only 4 wire smoke detectors that operate on 8 5 to 14 2 VDC Note The...

Страница 17: ...terminal 7 OUT1 12V is a 12V programmable output At the default configuration setting 00410 this output can provide up to 1 25 A during an alarm 650 mA for UL Listed systems if the backup battery is...

Страница 18: ...stead of panel ter minal 4 the supply voltage must be limited to 9 5 VDC maximum and the negative side of the power supply must be connected to panel ground terminal 3 Figure 14 Connecting an Interior...

Страница 19: ...PBX phone line These systems are designed only for digital type devices that operate any where from 5 volts DC and up The panel uses an ana log modem and does not have a digital converter adapter or i...

Страница 20: ...e corrections where neces sary Proceed to the Troubleshooting section of this manual if problems persist Connecting the Phone Line to the Panel with a DB 8 Cord After installing the RJ 31X jack you ar...

Страница 21: ...steps described in the following section Power Up the Panel Figure 18 Connecting the Power Transformer Powering Up the Panel Note Without AC power shut down will occur if battery voltage falls below...

Страница 22: ...dealer code default 4321 The system can be put into program mode only when it is disarmed To enter programming mode using an alphanumeric touchpad connected to the panel terminals 1 Make sure the syst...

Страница 23: ...pertain to that menu Only when a specific menu is displayed can you advance to those settings For example pressing from the SENSORS menu gives you access to learning sensors programming sensor text de...

Страница 24: ...R Zone 4 hardwire Group 01 Panic Zone 5 wireless Group 01 Keychain Touchpad Zone 6 wireless Group 13 Kitchen Window COMM FAILURE off Entry Delay 8 seconds Exit Delay 8 seconds Extended Delay 1 minute...

Страница 25: ...de 0000 Security Global Default 12345 The 5 digit downloader code is used in conjunction with downloader pro gramming The down loader operator must have the panel account number and downloader code in...

Страница 26: ...ys Silent feature is disabled for users if this setting is on OR can be controlled by users if the setting is off Silent Arming on Demand is not affected To turn SIA False Alarm Reduction off or on 1...

Страница 27: ...remises for a forgotten item When Exit Extension is on the panel restarts the exit delay timer if the user reenters the premises through a designated delay door before the exit delay time expires When...

Страница 28: ...lts in false alarms due to code entry errors If a duress code is absolutely necessary use it with an Interrogator audio verification mod ule AVM to reduce false alarms and accidental dispatches Note T...

Страница 29: ...2 on The display flashes the entered setting 2 Press and the display shows the new set ting Open Close Rpts 0103 cs phone 1 0113 cs phone 2 Phones CS Phone 1 2 Default off When this setting is on the...

Страница 30: ...er enter the desired pager phone number including pauses The dis play flashes the entered number 2 Press and the display shows the new number To delete a Pager Phone Number 1 With the display showing...

Страница 31: ...1 off or 2 on The display flashes the entered setting 2 Press and the display shows the new set ting Streamlining 0125 pager 1 0135 pager 2 0145 pager 3 Phones Pager Phone 1 3 Default on This setting...

Страница 32: ...l phone test Thus any successful panel report to the central monitoring station resets the Next Phone Test setting to the Phone Test Freq value The panel only conducts an Auto Phone Test if no other r...

Страница 33: ...lay shows the new set ting Cancel Message 02007 Phones Options Global Default on This setting determines whether or not the panel displays a cancel message after the user disarms the system to clear a...

Страница 34: ...G HANG RING OFF ON current setting press 1 off or 2 on The display begins flashing the entered selection 2 Press and the display shows the new set ting Supervisory Time 0300 Timers Global Default rand...

Страница 35: ...mber of days 1 255 The display flashes the entered setting 2 Press and the display shows the new set ting Output Trip Time 0304 Timers Global Default 4 sec This setting determines how long onboard and...

Страница 36: ...nnn SECONDS current setting enter the desired time value 45 184 using 8 second inter vals The display flashes the entered set ting 2 Press and the display shows the new set ting Extended Delay 0312 T...

Страница 37: ...e system When set to ON pressing the LOCK button arms the system directly to AWAY with no Entry and Exit Delay When set to OFF pressing the LOCK button increments the arming level from OFF to STAY and...

Страница 38: ...station or a pager whenever sensors or zones are bypassed To turn Bypass Reports off or on 1 With the display showing BYPASS REPORTS OFF ON current setting press 1 off or 2 on The display flashes the...

Страница 39: ...nsor trip does not occur within a 4 minute time period then the panel sends an error report to the central monitor ing station When this feature is turned off the panel does not send Two Trip Error re...

Страница 40: ...el reports to the central monitoring station or pager daily or weekly when the panel detects a wireless device supervisory condition To set RF Supv Report to daily or weekly 1 With the display showing...

Страница 41: ...sends a recent closing report to the central station or a pager if an alarm occurs within two minutes after the exit delay time expires Such a report is used to identify a possible exit fault To turn...

Страница 42: ...le A 3 Sensor Group Characteristics Note For UL Listed systems Alarm Verify must be turned off To turn Alarm Verify off or on 1 With the display showing ALARM VERIFY OFF ON current setting press 1 off...

Страница 43: ...te For UL Listed systems this feature must be off To turn Disable Trouble Beeps off or on 1 With the display showing DISABLE TR BEEPS OFF ON current setting press 1 off or 2 on The display flashes the...

Страница 44: ...il the LED flashes two times c Press and hold the UNLOCK button until the LED flashes once 6 Continue tripping sensors to learn them into the selected sensor group To stop learning sen sors into a gro...

Страница 45: ...mber P1 partition 1 G13 sensor group 13 NC normally closed HW hardwired and BACK DOOR is the programmed text name You can also change the zone sensor group assignment to eliminate the need to delete a...

Страница 46: ...ction Press and the display shows the new setting Key Beeps Acc Modules Bus Devices Default on This setting determines whether or not selected touchpads sound beeps when their buttons are pressed This...

Страница 47: ...d num ber Press and the display shows the new setting Note For California State Fire Marshall Listed installations this feature must be off Two Wire Smoke 0901 Onboard Options Inputs Default off This...

Страница 48: ...tant Each security access code Installer Dealer System Master or User must be unique Do not use the same combination of numbers for any two codes The USER CODES menu lets you program change regular us...

Страница 49: ...irect Bypassing 10nn1 nn user 00 thru 15 User Codes Default off User Codes perform basic arm ing and disarming functions The system allows up to 16 user codes user numbers 00 15 User numbers that show...

Страница 50: ...y flashes the entered selection Press and the display shows the new setting Silent Arming 21 Options Default off This setting determines whether the partition arms the system with off or without on so...

Страница 51: ...ic System Commands Testing Zones Sensors Testing Phone Communication Testing Central Station Pager Communication You should test the system after installing or servicing and after adding or removing d...

Страница 52: ...ireless Sensor Does Not Test 4 Press the STATUS button when you think all zones sensors are tested The touchpad displays any untested sensors zones and touchpad panics If all sensors zones and touchpa...

Страница 53: ...when displayed depending on pager service Account numbers are not displayed if Streamlining is turned on 1 Call the central station and tell the operator that you will be testing the system 2 Arm the...

Страница 54: ...ch 3 When the desired pitch is heard release the button If there is no touchpad activity for about 15 seconds the steady tone stops sounding Table 5 Pager System Event Codes Code System Event 009 Zone...

Страница 55: ...ng see the user programming OPTIONS menu Touchpad buttons don t beep when pressed 1 Check for touchpad power and or bus miswiring opens or shorts 2 Check that key beeps option is set to on see the ACC...

Страница 56: ...wire Zones System doesn t go into alarm when zone is tripped 1 System is disarmed Arm system and then trip the zone 2 Zone is not learned into panel memory Enter installer dealer program mode and use...

Страница 57: ...om backup battery 1 Check the AC circuit breaker to be sure the circuit is live 2 Check for proper panel and transformer wiring 3 Check that the transformer is plugged into a nonswitched outlet and se...

Страница 58: ...niffer 60 401 to verify that sensor is transmitting If sensor is not transmit ting check battery for low or no voltage and replace 2 Change mounting position of sensor from horizontal to vertical or v...

Страница 59: ...BXT na 1 2 mA for 10 detectors Panel limited to 100 mA 13 463 Visus LP60 PIR Motion Detector 10 mA 10 mA 13 464 DS940 PIR Motion Detector 17 mA 17 mA 13 468 Optex RX 040 PI PIR Motion Detector 17 mA 1...

Страница 60: ...e emergency buttons Police Instant 1 2 3 02 Fixed Panic 24 hour silent fixed emergency buttons Silent Instant 1 2 3 03 Portable Panic 24 hour silent portable emergency buttons Silent Instant 1 2 3 04...

Страница 61: ...l Instant Interior 24 hour local alarm zone protecting anything that opens and closes Police Instant 1 2 3 22 Local Delayed Interior Same as group 21 plus activation initiates a delay before going int...

Страница 62: ...plication Alarm Delay Restoral Supervisory CS Report Chime Active Levels D i n i n g R o o m H a l l B e d r o o m B e d r o o m B e d r o o m P a t h o f P e r s o n W a l k i n g M o t i o n S e n s...

Страница 63: ...4 Chime 074 Force 114 Mat 154 Screen 194 9 035 Closed 075 Foyer 115 Medical 155 Second 195 A 036 Closet 076 Freeze 116 Memory 156 Sensor 196 B 037 Closing 077 Front 117 Menu 157 Service 197 C 038 Code...

Страница 64: ...___ ____________ ____________ ____________ ____________ Immediate Trouble Beeps Off 0600 Installer Code 4321 0001 Keychain TP Arming Off 0403 Keyswitch Sensor None 0015 Latchkey Reports Pagers 1 2 3 a...

Страница 65: ...m Reduction 0003 Siren Timeout 4 minutes 0313 Siren Verify Off 0610 Smoke Verify Off 0900 SnapCard Output 1 01400 keychain Touchpad button activation 081000 SnapCard Output 2 00410 any audible alarm 0...

Страница 66: ...ff System Tests off 10070 10071 10072 ___________ ___________ ___________ User Code 08 None Direct Bypassing off System Tests off 10080 10081 10082 ___________ ___________ ___________ User Code 09 Non...

Страница 67: ...xterior Siren 016 Interior Siren 017 AVM Trip pulse 018 Table A7 Sensor Group Event Trigger Numbers Sensor Group Trigger No Group 00 in alarm 064 Group 01 in alarm 065 Group 02 in alarm 066 Group 03 i...

Страница 68: ...or 05 in alarm 133 open 233 Sensor 06 in alarm 134 open 234 Sensor 07 in alarm 135 open 235 Sensor 08 in alarm 136 open 236 Sensor 09 in alarm 137 open 237 Sensor 10 in alarm 138 open 238 Sensor 11 in...

Страница 69: ...rm 214 No Activity in alarm 216 Fire Panic in alarm 217 Police Panic in alarm 218 Auxiliary Panic in alarm 219 Opening Report in alarm 220 Closing Report in alarm 221 Latchkey Report in alarm 222 Dure...

Страница 70: ...s siren time response times activate outputs only if sirens are active for another reason 3 If an alarm event does not necessarily require disarming no activity closing report etc out puts set up for...

Страница 71: ...Rpts On Off Backup On Off 0114 0104 Reporting Format SIA CID 0115 0105 0124 Latchkey Rpts On Off 0134 Latchkey Rpts On Off 0144 Open Close Rpts On Off Open Close Rpts On Off Open Close Rpts On Off 012...

Страница 72: ...to Phone Test On Off Ring Hang Ring On Off Dialer Abort On Off Pager Delay 15 secs 0 30 02000 02003 02001 02005 02008 0210 0211 B A Auto Test Reset On Off 02002 Dialer Abt Delay 30 secs 15 45 02006 B...

Страница 73: ...level is NOT annunciated on exterior siren output B A B A B B B A B B Smoke Verify On Off 2 Wire Smoke On Off Sn nn Item n 0 A B Maximum of 4 bus devices 0 3 Press B to return to Security Menu A B Se...

Страница 74: ...k After disarming and canceling an alarm the system now displays all the alarms that have occurred since the last disarming Downloader Eavesdrop delay for carrier detect on downloader call in is now 5...

Страница 75: ...t 24 hours with no AC and specified standby load Radio Frequency 319 5 MHz Nominal Range 750 feet 305 meters typical open air Storage Temperature Range 30 to 140 F 34 to 60 C Operating Temperature Ran...

Страница 76: ...U S R e d B l a c k 4 1 2 V I n t e r i o r P i e z o S i r e n 3 0 0 0 6 M a x i m u m 1 0 m A O u t p u t 2 I s O p e n C o l l e c t o r T h a t H a n d l e s U p T o 2 0 0 m A D e f a u l t C o n...

Отзывы: