![GE 60-806-95R-16Z - Security Concord Express System Control... Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/ge/60-806-95r-16z-security-concord-express-system-control/60-806-95r-16z-security-concord-express-system-control_installation-instructions-manual_4006173038.webp)
Programming the Panel
33
Buffer Control (05001)
Reporting-Global (Default=off)
When this setting is on, only arming level changes are logged into the buffer
(memory) of the panel. When this setting is off,
all
system events are logged
in the buffer.
¾
To turn Buffer Control off or on:
1. With the display showing
BUFFER CONTROL
OFF/ON
(current setting)
, press
1
(off) or
2
(on). The display flashes the entered setting.
2. Press
ƒ
and the display shows the new set-
ting.
Back In Service (05002)
Reporting-Global (Default=on)
When this feature is turned on, the panel reports to the central station when
AC and backup battery power are restored (after an extended power outage).
¾
To turn Back In Service reports off or on:
1. With the display showing
BACK IN SERVICE
OFF/ON
(current setting)
, press
1
(off) or
2
(on). The display flashes the entered setting.
2. Press
ƒ
and the display shows the new set-
ting.
Bypass Reports (05003)
Reporting-Global (Default=off)
When this feature is turned on, the panel reports to the central station (or a
pager) whenever sensors or zones are bypassed.
¾
To turn Bypass Reports off or on:
1. With the display showing
BYPASS REPORTS
OFF/ON
(current setting)
, press
1
(off) or
2
(on). The display flashes the entered setting.
2. Press
ƒ
and the display shows the new set-
ting.
Low CPU Battery (05004)
Reporting-Global (Default=on)
When this setting is on, the panel reports a low panel battery to the central sta-
tion (or pager) before shutting down.
Note
For UL listed systems, Low CPU Battery must be set to “on.”
¾
To turn Low CPU Battery reports off or
on:
1. With the display showing
LOW CPU BATTERY
OFF/ON
(current setting)
, press
1
(off) or
2
(on). The display flashes the entered setting.
2. Press
ƒ
and the display shows the new set-
ting.
Battery Restoral (05005)
Reporting-Global (Default=off)
If this setting is on, the panel reports to the central monitoring station (or
pager) when the panel battery is restored or replaced or when a wireless sensor
reports a battery replacement to the panel.
¾
To turn Battery Restoral reports off or on:
1. With the display showing
BATTERY RESTO-
RAL OFF/ON
(current setting)
, press
1
(off)
or
2
(on). The display flashes the entered
setting.
2. Press
ƒ
and the display shows the new set-
ting.