![GE 60-806-95R-16Z - Security Concord Express System Control... Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/ge/60-806-95r-16z-security-concord-express-system-control/60-806-95r-16z-security-concord-express-system-control_installation-instructions-manual_4006173051.webp)
Testing the System
46
System Version Menu
The
SYSTEM VERSION
menu lets you view and identify panel hardware and software. This infor-
mation is primarily used for troubleshooting purposes.
Downloader Programming
The panel can be programmed remotely using ToolBox. Use the information you recorded in
Appendix A to inform the downloading operator of your installation programming requirements.
ToolBox Downloader Programming
Note
A Downloader Phone Num-
ber must be programmed
and the user-programmable
option Downloading must be
set to on in order for remote
downloader programming to
work.
¾
To initiate a ToolBox download session:
1. Contact your download station and ask the operator to prepare to download to the panel.
2. Make sure the system is disarmed.
3. Press
8
+
system master
CODE
+
7
+
0
(any)
,
1
(down), or
2
(up). The display shows
SYSTEM DOWNLOAD IN PROGRESS
during the downloading process.
If the alphanumeric touchpad does not display
SYSTEM DOWNLOAD IN PROGRESS
,
call the down-
loader operator to verify the downloader phone number and that ToolBox is set up properly.
Refer to the “Troubleshooting” section if the problem persists.
Testing the
System
This section describes the following subjects:
•
Basic System Commands
•
Testing Zones/Sensors
•
Testing Phone Communication
•
Testing Central Station/Pager Communication
You should test the system after installing or servicing and after adding or removing devices from
the system. UL Listed systems should be tested weekly.
Refer to the “Troubleshooting” section if correct test results are not achieved.
Chime On Close (25)
Options (Default=off)
This setting determines whether or not a single
chime is sounded when a perimeter door or
window is closed.
¾
To turn Chime On Close off or on:
1. Enter user programming mode with the system master code. The display
shows
TIME AND DATE
.
2. Press
A
or
B
until the display shows
OPTIONS
, then press
ƒ
. The display
shows
DOWNLOADING OFF/ON
.
3. Press
A
or
B
until the display shows
CHIME ON CLOSE OFF/ON
(current set-
ting)
.
4. Press
1
(off) or
2
(on). The display flashes the entered selection. Press
ƒ
and the display shows the new setting.
System Version (30=factory code,
31=system number, 32=system level)
(Default=N/A)
This menu lets you view and identify the panel
hardware and software version.
¾
To view and identify the System Version:
1. Enter user programming with the system master code. The display shows
USER CODES
.
2. Press
A
or
B
until the display shows
SYSTEM VERSION
.
3. Press
ƒ
and the display shows
FACTORY CODE nnn*nnnn
.
4. Press
B
and the display shows
SYSTEM NUMBER *nnnnnnn
.
5. Press
B
again and the display shows
SYSTEM LEVEL nnnn
.