Beeps during an exit delay; beeps rapidly for the last 10 seconds of an 

exit delay; and beeps 1 second at the end of the exit delay. 

 

Pulses when the armed status changes and the AC power is off. 

 

Pulses when the armed status changes and any zone(s) are bypassed. 

 

Pulses when the armed status changes and a low battery is detected. 

 

Pulses when the armed status changes and a Tamper condition is 

detected. 

 

Beeps to indicate Telephone Line Cut, if selected. 

 

Pulses when one or more of the following conditions are detected: Zone 

or Box Tamper, Low Battery, AC Power Fail, or Expander trouble. 

Entering a valid code will silence the keypad sounder when it is pulsing.  The 

arm/disarm state of your system will not change when entering a code to 

silence a pulsing keypad sounder.  Please contact your installer if a trouble 

condition exists. 
 
 

 

EMERGENCY EVACUATION PLANS 

 

An emergency evacuation plan should be established for an actual fire alarm 

condition.  For example, the following steps are recommended by the National 

Fire Protection Association and can be used as a guide in establishing an 

evacuation plan for your building. 

 

Draw up a floor plan of your home.  Show windows, doors, stairs, and 

rooftops that can be used for escape.  Indicate each occupant's escape routes.  

Always keep these routes free from obstruction.  Determine two means of 

escape from each room.  One will be the normal exit from the building.  The 

other may be a window that opens easily.  An escape ladder may have to be 

located near the window if there is a long drop to the ground below.  Set a 

meeting place outdoors for a headcount of the building occupants. 

 

Practice escape procedures. In a home, sleep with bedroom door closed; this 

will increase your escape time.  If you suspect fire, test the door for heat.  If 

you think it is safe, brace your shoulder against the door and open it 

cautiously.  Be ready to slam the door if smoke or heat rush in.  Practice 

escaping to the outdoors and meeting in an assigned spot.  Call the Fire 

Department from a neighbor's phone. 

NOTE

:  After the installation of your 

Security System has been completed, notify your local Fire and Police 

Departments to give them your name and address for their records.  Early 

warning fire detection is best achieved by the installation of fire detection 

equipment in all rooms.  This equipment should be installed in accordance 

with the National Fire Protection Association's Standard 72. For additional 

information write the National Fire Protection Association, Batterymarch Park, 

Содержание NetworkX NX-1300E

Страница 1: ...NetworX Series NX 1300E LED Keypad User s manual ...

Страница 2: ......

Страница 3: ...Arm s Battery Test Communicator Test Re Exit Siren Test s These features should not be enabled on UL listed systems ENTRY EXIT DELAY TIMES Exit Delay Time __________ Secondary Exit Delay Time ________ Entry Delay Time _________ Secondary Entry Delay Time _______ ZONE DESCRIPTIONS 01 _______________ 09 _______________ 17 _______________ 02 _______________ 10 _______________ 18 _______________ 03 __...

Страница 4: ...d sounds mean will help you to easily operate your system Keep in mind the level of security you will obtain with this system relates specifically with two major factors 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system You should be aware of the...

Страница 5: ...IN THE STAY MODE 8 USING THE QUICK ARM 9 CHANGING MODES WHILE SYSTEM IS ARMED 9 DISARMING THE SYSTEM 9 CANCEL ABORT FEATURE 9 BYPASSING ZONES 12 GROUP BYPASS 12 UNBYPASSING 12 TURNING THE DOOR CHIME ON AND OFF 12 CHANGING USER CODES 13 ASSIGNING USER CODE AUTHORITY LEVELS 13 OTHER KEYPAD FUNCTIONS 15 SETTING THE KEYPAD TONE 15 VIEW ALARM MEMORY 15 TEST FUNCTION 15 RESET FUNCTION 16 SET SYSTEM DATE...

Страница 6: ... being operated under duress Forced Arming An option that allows the system to be turned on ARMED with one or more zones open A system that is ready to be force armed will flash the ready light Note Those zones that are not ready will not create an alarm Function Code A Function Code is either a four 4 or six 6 digit code that has been programmed by the installer to operate a device Group Bypass A...

Страница 7: ...ollowed by the CANCEL key while this light is flashing all abortable reports will stop the communication process Note The abort feature must be enabled Entering a code followed by the CANCEL key during or after an alarm report to the central station will cause the cancel light to come on It will stay on until the central station has received the cancel report Note The cancel feature must be enable...

Страница 8: ... is on when the system is ready to arm and flashes if ready to force arm The ready light is off when the system is not ready to arm because of a zone s being faulted STAY LIGHT The stay light is on when the all interior motion detector zones are bypassed ZONE LIGHT The zone lights are off when everything is normal A zone light will be on if the zone has been bypassed If a zone light is flashing th...

Страница 9: ... two seconds If your system is connected to a monitoring center an emergency report could be transmitted to that center NOTE Some Panic Hold Up alarms are programmed to be silent at the protected site while reporting an alarm to the monitoring center Check with your installing company to determine how your security system will respond to the Panic Hold Up activation KEYPAD FUNCTIONS ARMING YOUR SY...

Страница 10: ...ing company listed on page 1 of this booklet for service Step 2 Enter your 4 or 6 digit user code If Auto Bypass is enabled all interior zones will be bypassed if you do not leave through a designated entry exit door If Auto Bypass is enabled omit Step 3 When Auto Instant is enabled if you do not leave through a designated entry exit door the instant light will illuminate indicating that the entry...

Страница 11: ...y by pressing the STAY key again DISARMING THE SYSTEM When you enter the protected area through one of the designated Entry Exit doors the keypad control will sound a continuous tone for the duration of the entry delay time or until you enter a valid code The red armed light will go off and the tone will stop The security system is now DISARMED If a valid code is not entered before the end of the ...

Страница 12: ...Page 10 CENTER SPREAD KEYPAD PHOTO GOES HERE ...

Страница 13: ...Page 11 CENTER SPREAD KEYPAD PHOTO GOES HERE ...

Страница 14: ...ass light will stop flashing upon exiting the Bypass Mode GROUP BYPASS By pressing the BYPASS key followed by the 0 key then the BYPASS key again all zones that are designated as group bypass zones will be bypassed Press the BYPASS key again to exit group bypassing UNBYPASSING To manually unbypass zones perform the bypassing procedure on a zone that is already bypassed The corresponding light for ...

Страница 15: ...ter r r r r for a 4 digit code or r r r r r r for a 6 digit code Step 5 The ready light will flash indicating you are back at Step 2 above If the code is rejected the sounder will beep 3 times Step 6 If another user code needs to be programmed return to Step 3 Step 7 Press the key while the ready light is flashing to exit the User Code Programming Mode ASSIGNING USER CODE AUTHORITY LEVELS Assign a...

Страница 16: ...re the user has access To change any of the partitions where the user has access press numbers corresponding to areas where you want to give the user access or deny access Example If zone light 2 is lit then the user is assigned access to partition 2 By pressing the 2 key the light will go off denying access to partition 2 Refer to chart shown below LIGHT PARTITIONS ASSIGNED 1 Partition 1 2 Partit...

Страница 17: ...econds Step 4 If another key is pressed the system will remain in the new partition until no keys have been pressed for 60 seconds VIEW ALARM MEMORY Step 1 Press r 3 The zone s that created the last alarm will be displayed on the keypad Step 2 The ALARM MEMORY feature will flash those zones that created alarms and will light steady those zones that were bypassed during the last alarm TEST FUNCTION...

Страница 18: ...nter the Day of Week 1 Sunday 3 Tuesday 5 Thursday 7 Saturday 2 Monday 4 Wednesday 6 Friday Step 3 Enter the Month Code Must always be two 2 digits 01 January 05 May 09 September 02 February 06 June 10 October 03 March 07 July 11 November 04 April 08 August 12 December Step 4 Enter the Day Code Must always be two 2 digits Example The 5th would be entered as 0 5 Step 5 Enter the last two digits of ...

Страница 19: ... press the r key followed by the 2 key to determine the service condition One or more zone lights will illuminate indicating what service s is required Call your service provider immediately for these problems Below is a listing of what each light means in a service condition TO EXIT THE SERVICE LIGHT MODE PRESS THE KEY LIGHT PROBLEM SYSTEM FAULT Press the 1 key The zone light s that is illuminate...

Страница 20: ...service light will remain lit until the trouble clears and a user code is entered SEE NOTE 7 FAILURE TO COMMUNICATE This light will illuminate when there is a failure to communicate between your system and the central station SEE NOTE 8 LOSS OF SYSTEM TIME This light will illuminate when there has been a loss of power and your system clock needs to be reset Instructions are on page 16 SEE NOTE NOT...

Страница 21: ... home Show windows doors stairs and rooftops that can be used for escape Indicate each occupant s escape routes Always keep these routes free from obstruction Determine two means of escape from each room One will be the normal exit from the building The other may be a window that opens easily An escape ladder may have to be located near the window if there is a long drop to the ground below Set a ...

Страница 22: ...Page 20 Quincy MA 02269 The following are examples of evacuation plans A plan unique to your home or business should be drawn and memorized by each occupant ...

Страница 23: ...Page 21 SYSTEM NOTES ...

Страница 24: ...NX 1300E SERIES USER S MANUAL NX1300EUC02 REV C 09 19 02 ...

Отзывы: