05-4446A01, Rev. E
Mercury Reference Manual
173
5.1.9 EIRP Compliance at 3650 MHz
To maintain regulatory compliance for Effective Isotropic Radiated
Power (EIRP) of
1-Watt per MHz
, the following table of transmit
power settings must be observed for the listed bandwidths and antenna
types approved. Consult the factory for other antenna options of lower
gain.
The antennas used to support operation in this band must be fixed mounted.
Table 5-5. Antenna Gain vs. Power Setpoint (3650 MHz)
Antenna Gain
(dBi)
Radio Configuration
(Antenna Type/Radio Bandwidth))
Radio Power Setpoint
(dBm)
13
Omni Antenna, 1.75 MHz BW
22
13
Omni Antenna, 3.5 MHz BW
23
13
Omni Antenna, 5 MHz BW
23
13
Omni Antenna, 7 MHz BW
23
13
Omni Antenna, 10 MHz BW
23
13
Omni Antenna, 14 MHz BW
23
18
Panel Antenna, 1.75 MHz BW
17
18
Panel Antenna, 3.5 MHz BW
20
18
Panel Antenna, 5 MHz BW
22
18
Panel Antenna, 7 MHz BW
23
18
Panel Antenna, 10 MHz BW
23
18
Panel Antenna, 14 MHz BW
23
Содержание Mercury 900
Страница 9: ...viii Mercury Reference Manual 05 4446A01 Rev E...
Страница 11: ...2 Mercury Reference Manual 05 4446A01 Rev E...
Страница 31: ...22 Mercury Reference Manual 05 4446A01 Rev E...
Страница 155: ...146 Mercury Reference Manual 05 4446A01 Rev E...
Страница 157: ...148 Mercury Reference Manual 05 4446A01 Rev E...
Страница 171: ...162 Mercury Reference Manual 05 4446A01 Rev E...
Страница 185: ...176 Mercury Reference Manual 05 4446A01 Rev E...
Страница 201: ...192 Mercury Reference Manual 05 4446A01 Rev E...
Страница 211: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www GEmds com 175 Science Parkway...