154
Mercury Reference Manual
05-4446A01, Rev. E
permanent memory (Flash memory) until cleared by user request.
Table 4-4
summarizes these classifications.
These events are stored in the transceiver’s Event Log and can be a valu-
able aid in troubleshooting unit problems or detecting attempts at
breaching network security.
4.1.4 Alarm Conditions
Most events, classified as “critical” will cause the
PWR
LED to blink,
and will inhibit normal operation of the transceiver. The LED blinks
until the corrective action is completed. (See also
Event Log Menu on
Page 113
.)
Table 4-4. Event Classifications
Level
Description/Impact
Storage
Alarms
Transceiver has detected one or
more alarm conditions
Flash
Memory
Informational
Normal operating activities
Flash
Memory
Temporary
Informational
Transient conditions or events
RAM
Minor
Does not affect unit operation
RAM
Major
Degraded unit performance but
still capable of operation
RAM
Critical
Prevents the unit from operating
RAM
Table 4-5. Alarm Conditions (Alphabetical Order)
Alarm Condition Reported
Event Log Entry
SNMP Trap
EVENT_BRIDGE
Network Interface /Error
networkInterface(17)
EVENT_FREQ_CAL
Frequency Not
Calibrated
frequencyCal(7)
EVENT_INIT_ERR
Initialization Error
initializationError(18)
EVENT_IPADDR
*
IP Address Invalid
ipAddressNotSet(4)
EVENT_IPMASK
*
IP Mask Invalid
ipNetmaskNotSet(5)
EVENT_LAN_PORT
lanPortStatus(78)
EVENT_MAC
MAC communication
Failed
macCommunication(1)
EVENT_MACADDR
MAC Address Invalid
noMacAddress(6)
EVENT_NETNAME
*
Netname Invalid
invalidNetname(12)
EVENT_POWER_CAL
Power Calibrated/Not
Calibrated
powerCal(8)
EVENT_REMOTE
Remote Added/
Removed (AP Only)
eventRemote(66)
EVENT_RSSI
*
RSSI Exceeds
threshold
rssi(11)
Содержание Mercury 900
Страница 9: ...viii Mercury Reference Manual 05 4446A01 Rev E...
Страница 11: ...2 Mercury Reference Manual 05 4446A01 Rev E...
Страница 31: ...22 Mercury Reference Manual 05 4446A01 Rev E...
Страница 155: ...146 Mercury Reference Manual 05 4446A01 Rev E...
Страница 157: ...148 Mercury Reference Manual 05 4446A01 Rev E...
Страница 171: ...162 Mercury Reference Manual 05 4446A01 Rev E...
Страница 185: ...176 Mercury Reference Manual 05 4446A01 Rev E...
Страница 201: ...192 Mercury Reference Manual 05 4446A01 Rev E...
Страница 211: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www GEmds com 175 Science Parkway...