05-2806A01, Rev. H
iNET Series Reference Manual
139
• Do not connect a radio to a power supply that is already pow-
ered up, unless necessary (that is, when connecting a radio to a
battery bank and charger). When power is applied by switching
on a power supply, the rise time of the supply is too slow to
cause overshoot.
• Typically, there are multiple return paths for the negative side
of the power supply, through the coaxial cable shield and the
chassis, for example. Any imbalance in the currents in the
power cable results in voltage overshoot, so this should be min-
imized during initial power-up if the supply cannot be turned
off.
• Add a 1 to 2
Ω
, 2 Watt resistor in series with the positive lead.
This greatly limits voltage overshoot. Since these radios draw
very little current in receive mode, and transmit only briefly,
there is little loss in power efficiency. In transmit, the voltage
drop is minimal and has no effect.
• Minimize the length of the power cabling, within reason.
• When power is applied from a power source having a relatively
high (1 or 2
Ω
) source impedance, or from a power source with-
out a large amount of output capacitance, no overshoot occurs.
Therefore, use a power supply that is rated appropriately for the
radio if possible—avoid using power supplies that far exceed
the radio's current requirements.
Please direct any questions you may have about interfacing to GE MDS
radios to the Technical Services Department via e-mail or telephone:
E-mail: [email protected]
Tel.
+1-585-241-5510.
4.2 RADIO (RF) MEASUREMENTS
There are several measurements that are a good practice to perform
during the initial installation. The will confirm proper operation of the
unit and if they are recorded, serve as a benchmark in troubleshooting
should difficulties appear in the future. These measurements are:
• Transmitter Power Output
• Antenna System SWR (Standing-Wave Ratio)
• Antenna Direction Optimization
These procedures may interrupt traffic through an established network
and should only be performed by a skilled radio-technician in coopera-
tion with the network manager.
Содержание MDS iNET-II 900
Страница 12: ...2 iNET Series Reference Manual 05 2806A01 Rev H...
Страница 32: ...22 iNET Series Reference Manual 05 2806A01 Rev H...
Страница 122: ...112 iNET Series Reference Manual 05 2806A01 Rev H...
Страница 124: ...114 iNET Series Reference Manual 05 2806A01 Rev H...
Страница 136: ...126 iNET Series Reference Manual 05 2806A01 Rev H...
Страница 138: ...128 iNET Series Reference Manual 05 2806A01 Rev H...
Страница 162: ...152 iNET Series Reference Manual 05 2806A01 Rev H...
Страница 164: ...154 iNET Series Reference Manual 05 2806A01 Rev H...
Страница 174: ...164 iNET Series Reference Manual 05 2806A01 Rev H...
Страница 182: ...172 iNET Series Reference Manual 05 2806A01 Rev H...
Страница 190: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www GEmds com 175 Science Parkway...