4–10
EPM 4
5
00 SUB METER – INSTRUCTION MANUAL
MODBUS MEMORY MAP
CHAPTER 4: COMMUNICATIONS
003A
0058
Date/Time of Oldest Interval - Hours/Minutes
R
Hours/Minutes
16-bit, Hours: 0-23 (bitmask = FF00)
Minutes: 0-59 (bitmask = 00FF)
DDE Data is COM Compatible,
Date/Time Numeric
003B
0059
Date/Time of Oldest Interval - Month/Day
R
Month/Day
16-bit
Month: 1=Jan., 12=Dec. (bitmask = FF00)
Day: 1-31 (bitmask = 00FF)
DDE Data is COM Compatible,
Date/Time Numeric
003C
0060
Date/Time of Oldest Interval - Year
R
Year
16-bit Unsigned Integer
003D
0061
Date/Time of Newest Interval - Hours/Minutes
R
Hours/Minutes
16-bit, Hours: 0-23 (bitmask = FF00)
Minutes: 0-59 (bitmask = 00FF)
003E
0062
Date/Time of Newest Interval - Month/Day
R
Month/Day
16-bit
Month: 1=Jan., 12=Dec. (bitmask = FF00)
Day: 1-31 (bitmask = 00FF)
DDE Data is COM Compatible,
Date/Time Numeric
003F
0063
Date/Time of Newest Interval - Year
R
Year
16 Bit Unsigned Integer
0040
0064
Date/Time of Currently Selected Interval - Hours/
Minutes
RW Hours/Minutes
16-bit, Hours: 0-23 (bitmask = FF00)
Minutes: 0-59 (bitmask = 00FF
0041
0065
Date/Time of Currently Selected Interval - Month/Day RW Month/Day
16-bit
Month: 1=Jan., 12=Dec. (bitmask = FF00)
Day: 1-31 (bitmask = 00FF)
DDE Data is COM Compatible,
Date/Time Numeric
0042
0066
Date/Time of Currently Selected Interval - Year
RW Year
16 Bit Unsigned Integer
0043
0067
Data Ready Flag
RW
16 Bits: Mask out/ignore Bit 15.
0=Data is ready for read
1=Populate registers with timestamp data
2=Invalid Timestamp Requested
Stored Dynamic Data Ready for Read
Average Interval Data
0063
0099
Interval Data Qualifying Register
R
16-bit Unsigned Integer, 8 = Invalid Interval
0064
*
0100
Meter #1 Three-Phase Total kW
R
kW
Stored Interval 1 for Meter #1
0066*
0102
Meter #1 Three-Phase Total kvar
R
kvar
Stored Interval 2 for Meter #1
0068*
0104
Meter #1 Three-Phase Total kVA
R
kVA
Stored Interval 3 for Meter #1
006A*
0106
Meter #1 Three-Phase Total Power Factor
R
%
Stored Interval 4 for Meter #1
006C*
0108
Meter #2 Three-Phase Total kW
R
kW
Stored Interval 1 for Meter #2
006E*
0110
Meter #2 Three-Phase Total kvar
R
kvar
Stored Interval 2 for Meter #2
0070*
0112
Meter #2 Three-Phase Total kVA
R
kVA
Stored Interval 3 for Meter #2
0072*
0114
Meter #2 Three-Phase Total Power Factor
R
%
Stored Interval 4 for Meter #2
0074*
0116
Meter #3 Three-Phase Total kW
R
kW
Stored Interval 1 for Meter #3
0076*
0118
Meter #3 Three-Phase Total kvar
R
kvar
Stored Interval 2 for Meter #3
0078*
0120
Meter #3 Three-Phase Total kVA
R
kVA
Stored Interval 3 for Meter #3
007A*
0122
Meter #3 Three-Phase Total Power Factor
R
%
Stored Interval 4 for Meter #3
007C*
0124
Meter #4 Three-Phase Total kW
R
kW
Stored Interval 1 for Meter #4
007E*
0126
Meter #4 Three-Phase Total kvar
R
kvar
Stored Interval 2 for Meter #4
0080*
0128
Meter #4 Three-Phase Total kVA
R
kVA
Stored Interval 3 for Meter #4
Table 4–1: Modbus Memory Map (Sheet 2 of 15)
Hex
Addr
Addr
Description
R/W
Units
Notes
Содержание EPM 4500
Страница 2: ......
Страница 14: ...1 10 EPM 4500 SUB METER INSTRUCTION MANUAL ORDERING CHAPTER 1 OVERVIEW ...
Страница 34: ...2 20 EPM 4500 SUB METER INSTRUCTION MANUAL INSTALLING THE SCAN TRANSPONDER CHAPTER 2 INSTALLATION ...
Страница 42: ...3 8 EPM 4500 SUB METER INSTRUCTION MANUAL RESETTING THE DEMAND VALUES CHAPTER 3 USING THE METER ...
Страница 66: ...4 24 EPM 4500 SUB METER INSTRUCTION MANUAL MODBUS MEMORY MAP CHAPTER 4 COMMUNICATIONS ...