9
Operating Modes
The thumbwheel selector switch is used to select the operation mode which best suits the customers purpose,
the details of the operational modes are as follows:
Mode “0”
#Auto close, (1-120 seconds, set by the knob on the front of the keypad, fully clockwise
is 120 second auto close time.)
#PE auto close, (meaning that when the gate is fully open and the photo electric cell beam is broken and
then made again the gate will close straight away)
#Multi-user, (meaning that the control circuitry will ignore any other input signals once the gate is opened
and will only close with the auto close.
Mode “1”
#Manual operation, (meaning input to open and input to close) except, when closing and the PE is broken
the gate will open up fully but will then auto close once the PE’s are cleared.)
Mode “2”
#Auto close, (meaning once the gate has opened the gate will close automatically once the set time has
expired) (The auto close time is set by the knob on the front of the keypad, fully clockwise is maximum
time, 120 seconds)
#No PE auto close, (meaning the gates will not close even if the PE cell beam is broken and made again.)
#No Multi-user, (meaning the auto close time can be overridden by another input to close the gates)
Mode “3
#Manual operation, (meaning input to open, input to close) If PE beam is broken while gate is closing the
gate will reopen and wait on another input to close.)
(The Pedestrian input will operate as per the open input for the above operating modes).
Variable Speed Drive Unit
The variable speed drive unit will, ramp up the speed of the operator, run at a predetermined fast speed
and then ramp down prior to closing. For approximately the last 500mm the gate will drive slowly into
the stops.
The acceleration and deceleration times have been set in the factory for a normal installation but can be
changed if necessary. Similarly, the speed that the gate operates at has also been set but can be changed.
Variable Speed Drive Unit
–
Key Pad Operation
The following diagram (Figure 1) shows the keys on the keypad, which is used to select the various
functions, please refer to these when reading further instructions.