F
A UL T
F
I NDI NG
In the event that the operator does not function due to a fault or unmet condition, there is a simple and
effective way of ascertaining where the probable fault may lie. As the invertor is a combination PLC that
provides the logic for executing the running of the gate motor, the inputs and their status are very important.
Understanding what each input does will help to clear or rectify any problem relating to the input. To see the
status of the inputs, proceed to parameter 39 via the k
eypad (refer to section on ‘keypad operation’ for
navigating your way there). The various strokes relate to the inputs, when the stroke is high it means the
input is on, and when low, the input is off. This screen can therefore be used to ascertain what inputs are on
or off, making the fault finding process much quicker.
Parameter 39 and 59 can be used for fault finding as shown below.