 gbo Medizintechnik AG

 

Version 2.1

 

 

3

 

Description of function 

3.1

 

Standby-push-button 

The 

standby-push-button

 is placed on the right side below the Touch Screen. If the device is in standby-

mode, 

the standby-push-button

 is shining. 

 
You can put the table in standby-mode by pressing 

the standby-push-button

. The stepped bed will lower 

down and all functions of the table are switched off. By pressing the 

standby-push-button

 again, the normal 

functions of the table will be reactivated. 
 
10 minutes after the end of the treatment the device will automatically activate the stand-by-mode, which 
means that the stepped bed will move down. This setting can be modified 

(see chapter 2.5.2).

 

 

3.2

 

Optical and acoustic user guidance 

Optical user guidance: 

 

Optical  user  guidance  is  effected  on  the 

Touch  Screen. 

The  setting,  which  is  changed  at  the  moment,  is 

displayed in 

green.

 

 

Acoustic user guidance:

 

 
The following table shows the acoustic signals and the relating meaning: 
 

Type of signal 

Reason 

Information sound 

 

In case of a failure; 

Triad gong

 

 

At  the  end  of  the  faultless  automatic  check  when  switching  on 
the device; 

 

At the end of the treatment time. 

Table 3:

 Acoustic user guidance  

 

3.3

 

Remote control 

The remote control is an infrared remote control with plastic foil keyboard. By the remote control the patient 
is able to change the settings at anytime before and especially during the treatment. The cuurrent meaning of 
the buttons are displayed on the Touch Screen (see Figure 2). 
 

 

By touching the 

Buttons

 

(<,>)

 setting/function can be selected. 

 

By touching the 

Buttons (+,

–)

 the value of setting/function can be changed. 

 

By touching the 

Button (OK)

 you confirm your choice. 

 
If you want to change the batteries: 
 
1.

 

Open the remote control by unscrewing the cross-head screw on the backside of the remote control. 

2.

 

Open  the  cover-plate  carefully.  Please  pay  attention  to  the  connecting  cables  between  the  cover-plate 
and the backside of the remote control. 

3.

 

Remove the holding-clamp for the batteries by dismantling the screw. 

4.

 

Replace the old batteries with two new micro-batteries. 

5.

 

Fix the holding-clamp. 

Содержание TESI Relax

Страница 1: ...gbo Medizintechnik AG Version 2 1 Massage Table TESI Relax User Manual...

Страница 2: ...omissions All rights reserved No part of this manual may be reproduced in any form or by any means electronic mechanical or otherwise without the prior written permission of gbo Medizintechnik AG gbo...

Страница 3: ...eans Caution Observe the instructions for use Note Information that will facilitate your work Glossary Touch Screen Display equipped with a touch panel The touch panel reacts to the smooth touch of th...

Страница 4: ...nection and switch on 10 2 2 1 Fuses 11 2 3 Placing out of operation 11 2 4 Waste removal of the device and accessories 11 2 5 Settings 12 2 5 1 The menu 12 2 5 2 Device settings 12 2 5 3 Basic settin...

Страница 5: ...21 5 1 Notes 21 5 2 Warnings 21 5 3 Errors 22 5 4 Other notes 22 6 MAINTENANCE 23 6 1 Legal provisions and requirements 23 6 2 Safety controls 23 6 3 Cleaning disinfection and care 24 7 WARNINGS AND S...

Страница 6: ...l massage vibration The system permits the optional or combined application of these modes While the patient feels very comfortable with the treatment for the therapist it offers high operational comf...

Страница 7: ...ard 1 Slot for Chip Card 2 Leg rest 9 Optional connector for support arm left 10a Lock for service access 11 Head rest 13 Figure 1 Device view Middle section Massage section 12 Stepped bed 3 Support a...

Страница 8: ...ing the height press the OK Button and the treatment will be started with the basic settings If you use the remote control Press the button to activate NO Press OK The request to adjust the height of...

Страница 9: ...elax 9 gbo Medizintechnik AG Version 2 1 Note You can handle the table at any time with the Touch Screen as well as with the remote control The activated function will appear in green colour on the di...

Страница 10: ...eas of anesthesia departments the possibility of an explosion cannot be excluded If the patient and or the patient cable is directly exposed to a radiator of a medical device for high frequency heat t...

Страница 11: ...3 With a screw driver the box can be pulled out of the receiver by the small slot 4 Only fuses that correspond to the specifications named in the technical data should be used Warning Risk of fire if...

Страница 12: ...ed on and is ready you can start the threapy immediately using the customized settings Note You can only start the menu if no treatment is in progress and the correct chip card is inserted You can han...

Страница 13: ...stored when the device starts up Settings Possible options Basic settings upon delivery Compression of the rolls 0 100 50 Speed cm s 0 15 5 Vibration Hz off 15 35 19 Spine area analog Height of steppe...

Страница 14: ...time account You can choose between 1 2 5 and 10 hours Confirm your choice with the OK Button 7 Eject the service or adjustment card 8 Insert the card that you want to create in the intended slot at...

Страница 15: ...and the relating meaning Type of signal Reason Information sound In case of a failure Triad gong At the end of the faultless automatic check when switching on the device At the end of the treatment ti...

Страница 16: ...etting Pressure of the rolls 0 100 Speed cm s 0 15 cm s Vibration Hz off 15 35 Hz Spine area analog Height of stepped bed cm 0 50 cm Temperature C 20 35 C Time of treatment min 1 30 min Volume of audi...

Страница 17: ...r the next treatment 4 Card with time credit With this chip card the patient can use the TESI Relax for pre paid time of treatment However no treatment settings can be stored on this card 3 6 Head pho...

Страница 18: ...red Raise of step 2 Touch the Button for massage The roller pressure will be set on 50 3 Touch the Buttons to set the treatment time 4 Touch the Buttons to set the roller pressure 5 Touch the Buttons...

Страница 19: ...NO on the Touch Screen or by pressing the Button Button NO will be activated pressing the Button OK Continue with point 5 b b Alternatively If you use a new personal card or card with time credit you...

Страница 20: ...rd TESI Relax will be deactivated 10 After the treatment the patient should remain in an upright position with his legs dangling over the side of the table for about 3 to 5 minutes and remain quiet an...

Страница 21: ...finger at a single point If more than one finger or the ball of the thumb are placed on the active surface this will trigger the error message shown above 2 Confirm the message with the Button OK Not...

Страница 22: ...hing the Button OK and try to move the carriage again by touching the Touch Screen 3 If the message appears again contact the Service Center 5 3 Errors There are two possible error messages Error CAN...

Страница 23: ...user 6 1 Legal provisions and requirements The device is subject to the provisions of the Medical Device Directive The safety controls have to be carried out on the basis of this directive Thereby th...

Страница 24: ...portions of alcohol Example for usefull products to be used for cleaning are Mikrobac Tissues by Hartmann Bode or Cleanisept Wipes by Dr Schumacher If the imitation leather of the heating cover is we...

Страница 25: ...signs used 0123 CE Conformity sign Observe the instructions for use Application section with protection class B This product complies with WEEE Directive 2002 96 EG waste electrical and electronic eq...

Страница 26: ...f the support arm can be used to get up Dimensions max 66 175 cm x 200 cm x 94 cm height x depth x width height of the device without with support arm Weight max 80 kg without accessories Color RAL 90...

Страница 27: ...lster small Compact flash card Relaxation CD Head phones set 018 0 0010 Chip card freely programmable 018 4 0006 Adjustment card 018 4 0006 EK Infrared remote control 018 1 0059 Head phones 018 4 0012...

Страница 28: ...of treatment 19 Creating chip cards 14 D Device settings 12 F Fuses 11 I Information sound 15 M Maintenance 23 massage rollers 18 N Note 8 9 12 14 18 20 R Remote control 15 S settings 12 Short instruc...

Страница 29: ...nical support by the manufacturer dealers or service authorized by the manufacturer The product s life time anticipated by the manufacturer is 10 years The TESI Relax tables are electronic devices For...

Страница 30: ...est IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ce...

Страница 31: ...z to 800 MHz d 2 3 P for 800 MHz to 2 5 GHz Where P is the maximum output power rating of the transmitter in watts according to the transmitter manufacturer and d is the recommended separation distanc...

Страница 32: ...32 TESI Relax gbo Medizintechnik AG Version 2 1...

Отзывы: