Servicing
Titan 165/ 110 Technical Service Manual
Page 1 - 4
© GBC Films Group October 2000
Footsw itch sp eed is lim ited w h en th e safety
sh ield is in th e raised p osition or rem oved .
C A U T IO N
f) Allow the laminator to cool slightly to no higher
than 110
o
F ( 43
o
C ) or cool to the touch.
CAUTION
Use only isopropyl alcohol or rubber cement
eraser to clean the rollers. Harsh chemicals
like toluene, acetone, or MEK can destroy
the silicone covering of the rolls.
g) With the rubber gloves on, clean the rolls
using a moderate amount of 80% isopropyl
alcohol on a cotton terry cloth.
CAUTION
Exercise care when cleaning the laminating
rollers with 80% isopropyl alcohol:
Use only in a well ventilated area
Wear rubber gloves
Use only on cool rolls
C L E A N I N G H E A T E D R O L L E R S C A N
I G N I T E T H E F U M E S !
W A R N IN G
W h en op eratin g th e lam in ator u sin g th e
footsw itch , keep h and s and fin gers aw ay
from th e n ip of th e rollers.
Y ou m ay b e C R U S H E D or B U R N E D !
h) For the lower rollers, replace the feed table and
rotate the rollers to an uncleaned area using the
footswitch.
Footsw itch sp eed is lim ited w h en th e safety
sh ield is in th e raised p osition or rem oved .
C A U T IO N