background image

Page 5 of 25

Section 

3  SAFETY DIRECTIONS & WARRANTY 

3.1 

General 

The following directions should enable the person responsible for the product, and 
the person responsible for use of the equipment, to anticipate and avoid operational 
hazards. 

The person responsible for the product must ensure that all personnel who install 
and maintain the product understand these directions and adhere to them. 

3.2 

Intended Use 

Permitted Uses

 

Bill Note Validation 

Adverse Uses

 

Adverse uses of the equipment include, but are not limited to: 

Use of the product without instruction

Use outside of the intended limits

Removal of hazard notices

Opening the product while it is connected to mains power

Modification or conversion of the product

Use of products with obviously recognizable damages or defects

 Warning

 

Adverse use can lead to injury, malfunction and damage.   
It is the task of the person responsible for the equipment to 
inform the user about hazards and how to counteract them. The 
product is not to be operated until the user has been instructed 
on how to work with it. 

3.3 

Responsibilities 

Person 
installing or 
maintaining 
the product

 

The person installing or maintaining the product has the 
following duties: 

To understand the safety instructions on the product and the
instructions in the user manual 

To be familiar with local regulations relating to safety and accident
prevention

To inform relevant person in charge immediately if the product and
the application becomes unsafe

To ensure that the national laws, regulations and conditions for the

operation are respected

 Warning

 

The person installing the product must ensure that the product 
is used for its intended purpose and that it is operationally safe. 

 Warning

 

This product may be installed only by an appropriately trained 
and qualified technician as per any national regulation. 

 Warning

 

Only Astrosys International authorized service workshops are 
entitled to repair these products. 

www.TURNSTILES.us / www.entrapass.com / 8641 S. Warhawk Road, Conifer, CO 80433 / 303-670-1099

Содержание ST1C-UL

Страница 1: ...GBA ST1C UL 110 VAC 12Vdc Operation Manual www TURNSTILES us www entrapass com 8641 S Warhawk Road Conifer CO 80433 303 670 1099...

Страница 2: ...TION 14 5 1 Power Requirements 14 5 2 Safety Standards 14 5 3 110VAC Power Connector 15 5 3 1 9 pin connector Details 15 5 3 2 Output Relay Rating 15 5 3 3 High Voltage Enable 15 5 4 12Vdc Low Voltage...

Страница 3: ...document mean ST1C UL version with integral 100 120 Volt AC power regulator where applicable If you have any questions about this or any other GBA and Microcoin products then please visit our web sit...

Страница 4: ...attack surface coatings Please observe detailed instructions in section Error Reference source not found Error Reference source not found Damp products Dry the product and the accessories at a temper...

Страница 5: ...nform the user about hazards and how to counteract them The product is not to be operated until the user has been instructed on how to work with it 3 3 Responsibilities Person installing or maintainin...

Страница 6: ...under warranty must be delivered to an Authorized Service Centre inbound freight prepaid Upon request owner must show proof of purchase when submitting equipment for service during the warranty perio...

Страница 7: ...less than 3 seconds Nominal Cassette Capacity 300 bills front or rear access Interfaces Supported Pulse Parallel NISR Serial BSCP ccTalk ccNet VCCS Refer to separate manuals for more details on each...

Страница 8: ...pecific application Bill Cassette 100 300 600 or 1000 bill capacity Faceplate matching Bill Guides to suit 66 or 70mm bill widths Internal Bill Guides to suit 66mm or 70mm applications Faceplate Bill...

Страница 9: ...tored notes 300 Bill Cassette shows a front access style 600 Bill Cassette shows a rear access style with lock fitted Remove the cassette by sliding the cassette clip forwards and lifting the cassette...

Страница 10: ...eze two tabs Press the release button Pull back to open the cassette lid Remove stacked bills Front Access Cassette Opening lid Front Access Cassette Remove stacked bills Rear Access Cassette Opening...

Страница 11: ...n be mounted in three ways i Standard the entire faceplate is revealed at the front of the host machine and can be used to mount information decals ii Security only the raised area of the faceplate an...

Страница 12: ...ogramming and calibrating the validator This requires a programming loom which connects to a Microcoin VAL 364 USB to Serial Dongle See section 4 7 User Push Button and Diagnostic LED See separate tec...

Страница 13: ...amming Loom Connects to Microcoin VAL 364 ASY M 141418 12Vdc Power Signal Loom Connects to 18 pin port Power Signal Loom Part ASY M 141403 Bill Acceptor Side Host Side Bill Acceptor Side Host Side Unt...

Страница 14: ...ply that is adequately protected taking into consideration local installation wiring conditions 5 1 Power Requirements Power Consumption Typical 15W Supply Voltage 100 to 120 Volts AC Input current Ty...

Страница 15: ...05 at 2 A 120 VAC Res Operate Time typical 5 ms at nominal coil voltage Release Time typical 1 ms at nominal coil voltage with no coil suppressions Note 1 All values at 20 C 68 F Note 2 Please observe...

Страница 16: ...when active 2 When using Low Voltage Enable input on this connector do not connect High Voltage Enable pins to avoid conflicts in the control logic See table below 3 The Enable Validator input can be...

Страница 17: ...rt is compliant as a USB 2 0 full speed host or device and is fitted with a mini AB socket The USB port can be used to Connect a USB memory device to reprogram the validator with new firmware and bill...

Страница 18: ...ut of the Channel Assembly see section 6 2 4 Using a cotton swab or lint free cloth wetted with cleaning solution and applying light force only carefully clean all sensor windows in both halves upper...

Страница 19: ...ard until the retaining bar clicks into place Note that the black internal bill guides must be fitted for either 66 or 70mm applications They can be provided as a kit which includes a matching note gu...

Страница 20: ...purple Access Latch on the back of the Bottom Sensor Assembly and gently slide the module out of the Channel Assembly 4 Clear the jammed bill s from the bill acceptor 5 Re assemble unit and switch th...

Страница 21: ...Indication Status Standby Modes Steady Green Unit Operational Steady Orange Unit Inhibited by Host Controller Steady Red Unit out of order Hard Fault Active Modes Flashing Green Unit Validating Flash...

Страница 22: ...by the user as it was scanned 4 Red Bill inserted skewed 5 Red Bill is too long or two bills inserted 6 Red 7 1 3 Illuminated Bill Guide Patterns The illuminated bill guide can be configured to flash...

Страница 23: ...s 3 Insufficient power supply capacity 1 Bill inhibit settings 2 Bottom Sensor Assembly fitting 3 Bill path cleanliness 1 Use on board button or GBA Talk to enable required bills 2 Use GBA Talk to che...

Страница 24: ...Page 24 of 25 Section 8 8 DIMENSIONAL DRAWINGS 8 1 Upstacker Downstacker www TURNSTILES us www entrapass com 8641 S Warhawk Road Conifer CO 80433 303 670 1099...

Страница 25: ...S us focuses on the needs of our clients Our vast experience with a variety of installation types gives us a tremendous working knowledge of available technology we work with the customer s IT Facilit...

Отзывы: