Chapter 6 – Testing and Repair, Page 6-34___________________________________________________
UV Module Ventilation Fans – Cont.
8.
Pull back the plastic cover, trace the two black wires from the fan back to their connection point and
remove the wire nuts.
9.
Sliding a small screwdriver through the front flange, remove the four fan mounting screws (Refer to
Figure 6-35-1).
Figure 6-34-1
Removing Ballast Raceway
Five Nuts that Hold
the Ballast
Raceway to the
Face of the Module
Figure 6-34-2
Ballast Raceway Removed from Module