Instructions for GT1000DC
www.gatexpertstore.com
21
Insert the wire into the
number on the terminal that
you are looking to connect to.
Refer to Page 15.
Tighten with a screwdriver
to secure the wire in place.
J10 Terminal:
OP:
Open Limit Switch.
COM:
Limit Switch Common Terminal.
CL:
Close Limit Switch.
J7 Terminal:
External Push Button.
Terminal 1:
External Open Push Button Switch.(N.O.)
Terminal 2:
External Close Push Button Switch.(N.O.)
Terminal 3:
External Stop Push Button Switch.(N.O.)
Terminal 4:
Common Terminal for External Push Button.
Wiring to the Terminal
Using a screwdriver to
loosen the screw on the
side of the terminal.