A new hose and end fittings (stem/ferrule) must be
used when building a hose assembly. Re-using any
components will seriously affect performance and could
result in serious injury or damage.
Cut hose to desired length.
Using Gates crimp data chart (#35019 (Ind),
428-7365 (Auto)), select the correct coupling or visit
our website to download our electronic program at
ecrimp.gates.com.
Place ferrule over the end of the hose.
Lubricate the first two or three serrations on stem
with lightweight oil (SAE 10W).
Clamp stem in vise on hex portion, and push hose
onto stem.
Hose should be flush against stem shoulder (see
cutaway drawing below).
Hose and coupling are now ready for crimping.
HOSE PREPARATION
MOBILE CRIMP 4-20 SAFETY AND OPERATING MANUAL
1.
2.
6.
GLOBAL SPIRAL
TM
TWO-PIECE COUPLINGS
CAUTION
3.
4.
5.
10