FASTEN CRIMPER TO WORK SURFACE STATION
BEFORE USE
(to avoid damage to machine or
personal injury because an unsecured machine
can fall).
Position crimper so that mounting holes are
approximately 7” to 8” from the edge of the
work surface.
Mark the drilling location using the mounting holes
as a guide (see illustration below).
Drill two 5/16” diameter holes then use mountig
holes or clamps to fasten stand to work surface.
ATTACH PUMP TO CRIMPER
Place pump near crimper and connect hose
assembly to the pump port (3/8” NPT threads).
Pipesealant may be used to seal connection.
(Forbest connection, use Gates’ Quick Disconnect
couplings, G95311-0606 and G95321-0606,
sold separately.)
Connect opposite end to the adapter or crimper.
CHECK PUMP OIL LEVEL
Pump comes with oil in reservoir. Check proper oil
level per pump operating manual instructions or the
Maintenance section of this manual.
CONNECT PUMP TO POWER OUTLET
For 115V connection, plug power cord into a properly
grounded and rated circuit. For vehicle battery
connection, see pump operating manual.
EDGE OF
WORK
SURFACE
(2) 5/16" DIAMETER HOLES
7 1/2"
11"
Clamps
3.
4.
5.
To avoid damage to the machine ALWAYS fasten
the crimper to the work surface before you
attempt to crimp.
THINK SAFETY!
Mounting Holes
6.
6
SETUP
MOBILE CRIMP 4-20 SAFETY AND OPERATING MANUAL