80 Series Ports and PRO ACTION
Gates larger port series – the 80 series – can be used with PRO ACTION. The 80
series port system includes both SP80-8 in and SP80-10 in spherical diameter dome
ports. This can be useful in certain applications where the benefits of a larger dome are
realized.
Remove the 60-SERIES Port Base from PRO ACTION.
The four corner screws
will release it from the housing. Install the 80-SERIES Port Base, followed by an
80-SERIES Port Ring and Port.
Next, install the taller feet on PRO ACTION.
This keeps the housing from resting
on the larger port system.
1. Remove four corner screws to
release the 60-SERIES Port Base.
Install the optional 80-SERIES Port
Base. Tighten screws snug.
2. Mount an 80-SERIES Port Ring
to the housing. 1/4 turn bayonet
mount.
3. Mount an 80-SERIES Port to the
housing. Shown is the SP80-10 in
Dome Port. 1/4 turn bayonet
mount.
NOTE – This screw is a FLAT
HEAD screw, not socket cap like
the other three.