6.5.7
Advanced
Navigate to:
Main Menu Setup Alarm Advanced
This subsection enables you to set up the trigger for alarm events based on G Sensor input, and also to
define the actions that will be taken when the alarm occurs.
G-Force
Name
Checkbox
–
if selected, enables the device to monitor for
G Sensor trigger events. In the case of G Sensor
exceeding the threshold values, this alarm will be
triggered.
DEFAULT SETTINGS:
Checkbox
–
Unselected
Alarm Type
Drop-down list to select the classification level for the
alarm:
Event
Alarm
DEFAULT SETTINGS:
Alarm
Trigger
Click the
(Setup)
button under Trigger to display the
Trigger setup screen to set up the G Sensor threshold
values:
X
–
numeric text field to set the threshold value
for the G forces along the x-axis.
Y
–
numeric text field to set the threshold value
for the G forces along the y-axis.
Z
–
numeric text field to set the threshold value
for the G forces along the z-axis.
DEFAULT SETTINGS:
Disabled.
Linkage
Click the
(Setup)
button under Linkage to go to the
Linkage setup screen. This sets up the video display,
recording and snapshot options associated with this
alarm.
The Linkage setup screen enables you to configure the
following options:
Channel
–
checkboxes that allow you to select
any combination of the camera channels to be
included in the display and recording.
Post Recording
–
numeric value box which
allows you to enter the duration for which video