AI282s v3 and SP25 Stop Arm Camera System Install Guide
8
5 Setup AI282s / SP25 Alarm Recording in the DVR
This section describes how to setup the AI282s camera via G4 Connect or ICD. If using an ICD,
the steps are the same.
1.
To calibrate AI282s in
Preview,
please reference
4 AI282s Calibration Using G4Connect
2.
Navigate to
Preferences-> Alarm-> Base-> Violation
. Enable “Violation F” and then
click on
“Setup” in Trigger under Violation F
.
3.
In Trigger-> Setup, set Debounce Time to 10 seconds.