G4-304SD1
User Manual & Install Guide
73 of 149
device will turn off to protect the battery from
being discharged.
DEFAULT SETTINGS:
Checkbox
–
Unselected
Battery Low Voltage
Protect
Numeric text field to set the battery low voltage
threshold. If Low Volt Protect is selected, the
device will turn off when battery voltage is
detected to be consistently below this
threshold value.
For a vehicle with a 12V battery, the
recommended threshold value is 9V. For a
vehicle with a 24V battery, the recommended
threshold value is 21V.
DEFAULT SETTINGS:
Disabled/not applicable.
Voltage Startup
Numeric text field to set the recovery boot
voltage threshold. When the vehicle battery
recovers its charge and is consistently above
this threshold value, the device will
automatically turn on again.
For a vehicle with a 12V battery, the
recommended threshold value is 12.5V. For a
vehicle with a 24V battery, the recommended
threshold value is 24.5V.
DEFAULT SETTINGS:
Disabled/not applicable.
Low Volt Upload
Checkbox – selected will enable the device to
log and report if low voltage situation occurs.
DEFAULT SETTINGS:
Checkbox
–
Unselected