Motor Control
It is your responsibility to contact a qualified
electrician and assure that the electrical installation is
adequate and in conformance with all national and local
codes and ordinances.
Correct installation is your responsibility.
Make sure you
have the proper installation conditions and that
installation clearances do not block air flow.
Mounting
This product must be installed on a flat, horizontal
surface. Mounting the product to a stable, rigid
operating surface and using shock mounts will reduce
noise and vibration.
INSTALLATION
c
Disconnect electrical power at the circuit breaker
or fuse box before installing this product.
Install this product where it will not come into
contact with water or other liquids.
Install this product where it will be weather
protected.
Electrically ground this product.
Failure to follow these instructions can result in
death, fire or electrical shock.
WARNING
Electrical Shock Hazard
Plumbing
Remove plug from the OUT port. Connect with pipe
and fittings that are the same size or larger than the
product’s port.
Accessories
Install relief valve and gauge at outlet to monitor
performance. A check valve may be required to prevent
back streaming through the compressor.
WARNING
DANGER
Your safety and the safety of others
is extremely important.
We have provided many important safety messages
in this manual and on your product. Always read
and obey all safety messages.
This is the safety alert symbol. This symbol
alerts you to hazards that can kill or hurt you and
others. The safety alert symbol and the words
“DANGER” and “WARNING” will precede all safety
messages. These words mean:
You will be killed or seriously injured if you don’t
follow instructions.
You can be killed or seriously injured if you don’t
follow instructions.
All safety messages will identify the hazard, tell you
how to reduce the chance of injury, and tell you
what can happen if the safety instructions are not
followed.
2
c
This product must be properly grounded.
Do not modify the plug provided. If it will not
fit the outlet, have the proper outlet installed
by a qualified electrician.
If repair or replacement of the cord or plug is
necessary, do not connect the grounding wire
to either flat blade terminal. The wire with
insulation that is green with or without yellow
stripes is the grounding wire.
Check the condition of the power supply wiring.
Do not permanently connect this product to
wiring that is not in good condition or is
inadequate for the requirements of this product.
Failure to follow these instructions can result in
death, fire or electrical shock.
WARNING
Electrical Shock Hazard
ELECTRICAL CONNECTION
Grounded Plug
Grounding Pin
Grounded Outlet
120-volt grounded connectors
shown. 220 / 240-volt grounded
connectors will differ in shape.
DIAGRAM A
Model with a power supply cord:
This product must be grounded. For either 120-volt or
220/240-volt circuits connect power supply cord
grounding plug to a matching grounded outlet. Do not
use an adapter. (See DIAGRAM A)