Low
High
Pump
Motor
Excess
Reason and remedy
Pressure Pressure Overheat Overload Noise
for problem.
•
Filter dirty.
Clean or replace.
•
Valves dirty or valves bent.
Clean or replace.
•
•
•
Worn or torn diaphragm.
Repair or replace.
•
Relief valve set too high.
Inspect and adjust.
•
Relief valve set too low.
Inspect and adjust.
•
Plugged pressure line.
Inspect and repair.
•
Low voltage, won’t start.
Check power source.
•
•
•
•
Voltage wrong.
Check power source.
•
•
Rod magnet misalignment.
Realign.
•
Leaky hose or check valve.
Replace.
•
•
•
•
Dirt or liquid in compressor.
Inspect and clean.
•
•
Blown or leaking head gasket
or tubes. Replace.