background image

3

Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood, or
if you are not sure whether the product is properly
grounded.  Do not modify the plug provided.  If it will not
fit the outlet, have the proper outlet installed by a qualified
electrician.

In the event of an electrical short circuit, grounding
reduces the risk of electric shock by providing an
escape wire for the electric current.  This product may
be equipped with a power supply cord having a
grounding wire with an appropriate grounding plug.
The plug must be plugged into an outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.

Model that is permanently wired:

This product must be connected to a grounded,
metallic, permanent wiring system, or an equipment
grounding terminal or lead on the product.

Extension cords:

Use only a 3-wire extension cord that has a 3-blade
grounding plug.  Connect extension cord plug to a
matching 3-slot receptacle.  Do not use an adapter.
Make sure your extension cord is in good condition.
Check that the wire gage of the extension cord is the
correct size wire to carry the current this product will
draw.  An undersized cord is a potential fire hazard, and
will cause a drop in line voltage resulting in loss of
power causing the product to overheat.  DIAGRAM B
indicates the correct gage cord for length required and
the ampere rating listed on the product nameplate.  

If in

doubt, use the next heavier gage cord.  The smaller the
gage number, the heavier the wire gage.

DIAGRAM B – Minimum Gage For Extension Cords

Amps

Volts

Length of cord in feet

120v

25

50

100

150

200

250

300

400

500  

240v

50

100

200

300

400

500

600

800

1000

0-2

18

18

18

16

16

14

14

12

12

2-3

18

18

16

14

14

12

12

10

10

3-4

18

18

16

14

12

12

10

10

8

4-5

18

18

14

12

12

10

10

8

8

5-6

18

16

14

12

10

10

8

8

8

6-8

18

16

12

10

10

8

6

6

6

8-10

18

14

12

10

8

8

6

6

4

Power supply wiring must conform to all required safety
codes and be installed by a qualified person.  Check
that supply voltage agrees with that listed on product
nameplate.

WARNING – Read and follow all safety instructions. To
guard against injury, basic safety precautions should be
observed.  

Precautions for aquarium use:

1. If the air pump falls into the water, DO NOT reach 

into the water to retrieve it.

2. Carefully examine the appliance after installation.  It 

should not be plugged into electrical power if there 
is water found on any part of the pump.

3. DO NOT operate any air pump if it has a damaged 

cord or plug, or if it is malfunctioning or has been 
dropped or damaged in any manner.

4. To avoid the possibility of the air pump plug or 

receptacle getting wet, position the aquarium stand 
and tank to one side of a wall-mounted receptacle to 

prevent water from dripping onto the receptacle or 
plug.  A “drip loop,” shown above in the AQUARIUM 
SETUP DIAGRAM, should be arranged by the user 
for each cord connecting an aquarium air pump to a 
receptacle.  The “drip loop” is that part of the cord 

below the level of the receptacle, or the connector if 
an extension cord is used, which prevents water 
travelling along the cord from coming into contact 
with the receptacle.

5. If the plug or receptacle do get wet, DO NOT grasp 

the plug to disconnect the air pump.  Instead 
disconnect the fuse or circuit breaker supplying 
power to the receptacle.  Then unplug the air pump 
and examine for the presence of water on the plug 
or receptacle.

DANGER – To avoid possible electrical shock, special
care should be taken since water is employed in the
use of aquarium equipment.  If the air pump, cord or
plug are damaged in any way whatsoever, DO NOT
attempt repairs by yourself, return the air pump to a
Gast Authorized Service Facility for inspection and
repair.

AQUARIUM SETUP DIAGRAM

Guidelines for aquarium use:

1. Close supervision is necessary when any air pump 

is used by or near children.

2. To avoid injury, DO NOT disassemble the air pump.
3. Always unplug an air pump from an outlet when not 

in use, before putting on or taking off parts and 
before cleaning.  NEVER yank a cord to remove the 
plug from the receptacle.  Grasp the plug and pull to

disconnect.

IMPORTANT SAFETY INSTRUCTIONS

FOR AQUARIUM USE

Содержание DDL30

Страница 1: ...n Consult your Gast Distributor Representative before using at high altitudes IMPORTANT PLEASE READ THIS MANUAL AND SAVE FOR FUTURE REFERENCE Thank you for purchasing this Gast product It is manufactured to the highest standards using quality materials Please follow all recommended maintenance operational and safety instructions and you will receive years of trouble free service www gastmfg com IS...

Страница 2: ...y all safety messages This is the safety alert symbol This symbol alerts you to hazards that can kill or hurt you and others The safety alert symbol and the words DANGER and WARNING will precede all safety messages These words mean You will be killed or seriously injured if you don t follow instructions You can be killed or seriously injured if you don t follow instructions All safety messages wil...

Страница 3: ...by a qualified person Check that supply voltage agrees with that listed on product nameplate WARNING Read and follow all safety instructions To guard against injury basic safety precautions should be observed Precautions for aquarium use 1 If the air pump falls into the water DO NOT reach into the water to retrieve it 2 Carefully examine the appliance after installation It should not be plugged in...

Страница 4: ...n a tank is securely installed before operating it 7 Read and observe all the important notices on the air pump It is your responsibility to Regularly inspect and make necessary repairs to product in order to maintain proper operation Make sure that pressure is released from product before starting maintenance Never add oil to this oil less compressor Cleaning Do Not use kerosene or ANY other comb...

Страница 5: ...repair DIAGRAM E DIAGRAM D DIAPHRAGM MOUNTING BLOCK DIAPHRAGM L TUBE U NUT DIAPHRAGM MOUNTING BLOCK WASHER ROD U NUT CASING BLOCK Service Kit contents vary with compressor models Replacing Head and Diaphragm Assemblies DDL5 SERIES Refer to Diagram C Disassembly 1 Remove hex nuts from cover Refer to Fig 11 2 Remove cover and cover gasket 3 Gently lift out electromagnet and casing block 4 Remove hea...

Страница 6: ...TIVATING ARM 14 SCREW 15 VIBRATION CONTROL RUBBER 16 COIL FRAME 17 U NUT 18 POWER CORD 19 CORD RELIEF 20 CORD STOPPER 21 CENTER PLATE 22 GASKET 23 LOWER HOUSING 24 RUBBER FEET Your model may vary in appearance and configuration However internal components will be similar to those shown Parts shown are for stock models For specific OEM models please consult the factory When corresponding or orderin...

Страница 7: ...MPLIED BY ANY LITERATURE DATA OR PERSON GAST S MAXIMUM LIABILITY UNDER THIS EXCLUSIVE REMEDY SHALL NEVER EXCEED THE COST OF THE SUBJECT PRODUCT AND GAST RESERVES THE RIGHT AT ITS SOLE DISCRETION TO REFUND THE PURCHASE PRICE IN LIEU OF REPAIR OR REPLACEMENT GAST WILL NOT BE RESPONSIBLE OR LIABLE FOR INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND however arising including but not limited to those for...

Страница 8: ...lignment Realign Leaky hose or check valve Replace Dirt or liquid in compressor Inspect and clean Blown or leaking head gasket or tubes Replace TROUBLESHOOTING CHART www gastmfg com ISO 9001 14001 CERTIFIED 8 PART NO 70 1570 F1 210 REV C We have Gast Authorized Repair Facilities throughout the world For the most up to date listing contact one of our sales offices below World Headquarters P O Box 9...